油化学
Online ISSN : 1884-2003
ISSN-L : 0513-398X
曇り点測定方法の検討
固体脂専門委員会合同実験結果について
武谷 宏二横溝 和久青山 稔阿部島 〓于大捕 雅志坂田 正史鹿間 達雄田中 幸隆平田 芳明森 弘之
著者情報
ジャーナル フリー

1990 年 39 巻 7 号 p. 491-498

詳細
抄録
Three modified methods for measuring cloud point using a cooling bath in accordance with JIS (K 2269-1980) were compared with the present JOCS method for many kinds of oils. The results of five collaborative studies conducted by 10 laboratories indicated that statistical deviation among these methods were very little and that no significant defferences could be found between these and presently used methods.
These modified methods facilitate cloud point measurement since the temperature of the cooling bath can be more easily controled than the conventional methods.
著者関連情報
© 公益社団法人 日本油化学会
前の記事 次の記事
feedback