日本冷凍空調学会論文集
Online ISSN : 2185-789X
Print ISSN : 1344-4905
ISSN-L : 1344-4905
論文
ヒートポンプサイクルの特性評価に関する研究
多段式システムのランキン理想サイクル解析
菊池 健太郎矢部 彰
著者情報
ジャーナル フリー

1991 年 8 巻 2 号 p. 123-130

詳細
抄録
Three heat pump ideal cycles of two stage compression with two stage expansion, three stage compression with single stage expansion and three stage condensation systems, all of which are considered as the performance improvement methods, are analyzed by introducing the evaluation formula of COP, and the physical property of working fluids. Temperature lift, condensation temperature, COP, working fluids and cycle name are taken as the analysis parameters. No losses for compressors, evaporator and condenser are assumed for ideal cycles. Analytical results are processed for graphical presentation and data bases are made for the performance comparison and evaluation of multistage systems.
著者関連情報
© 1991 公益社団法人 日本冷凍空調学会
前の記事 次の記事
feedback
Top