Journal of The Japan Institute of Electronics Packaging
Online ISSN : 1884-121X
Print ISSN : 1343-9677
ISSN-L : 1343-9677
Electrochemical Monitoring Method for Filling Capability of Copper Electroplating Solution for Via Filling
Toshikazu OKUBOYuka MIZUNOKatsuyoshi NAOI
Author information
JOURNAL FREE ACCESS

2005 Volume 8 Issue 4 Pages 318-324

Details
Abstract
We have developed a method to monitor the time-dependent change in the filling capability of a via-hole filling copper electroplating solution. In this method, a rotating disk electrode is used to produce a controlled solution flow, and a constant current is applied to the rotating electrode in order to measure the potential value which is necessary to judge the filling capability. The obtained time-potential curves could be approximately fitted to a Boltzmann function to acquire the quantitative parameters required for judging the filling capability.
Content from these authors
© The Japan Institute of Electronics Packaging
Previous article Next article
feedback
Top