Transactions of the Visualization Society of Japan
Online ISSN : 1346-5260
ISSN-L : 1346-5252
Volume 22, Issue 2
Displaying 1-1 of 1 articles from this issue
Scientific Papers
  • Ryosuke MATSUMOTO, Yoshitomo SHINTANI, Masaki OKADA, Keizo IMAHORI, Ta ...
    Article type: Introduction
    Subject area: Theory and Principals
    2002 Volume 22 Issue 2 Pages 15-22
    Published: 2002
    Released on J-STAGE: February 22, 2002
    JOURNAL FREE ACCESS
    In a tube-nested combustor of a compact water-tube boiler, water tubes are placed closely to the burner and thus conventional empty furnace is, in principle, removed. In this type of boiler the convective heat transfer becomes a dominant design factor owing to the existence of tube banks in a burning zone and resulting agitation of flow. The flow pattern in a tube nest closely to the burner jet is substantially different from that in a uniform flow. Then, a cold model test using full-scale simulated tube-nested combustor has been conducted to understand the fundamental characteristics of flow pattern and structure of re-circulations flow at the burner exit. A stable and symmetric re-circulation flow at the burner exit is observed in a suitable tube arrangement, and the three-dimensional structure of this re-circulation is investigated.
    Download PDF (3643K)