2018 Volume 21 Issue 6 Pages 590-593
We evaluated the effects of temperature on the acceleration of performance in an electrochemical migration (ECM) reliability test of an FR-4 type printed wiring board (PWB). We evaluated the accelerated test conditions from 30°C to 140°C. Our test showed that the ECM failure mode at 30°C was different from the ECM failure mode at 85°C to 140°C.