  • Tsubasa OYAMA, Rie NAGAI, Mayumi FUJIMOTO, Ryoko KONISHI, Masashi MITA ...
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1129-1135
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    A fully-automated on-line oxidation column-switching HPLC system has been developed for the determination of endogenous melatonin in human plasma and saliva. This HPLC system consists of four processes. In the first step, melatonin is fractionated using a reversed-phase C4 column (Proteonavi, 75 mm × 1.0 mm i.d.). In the second step, the obtained melatonin fraction is on-line collected, and oxidized to a highly-fluorescent compound, N-[(6-methoxy-4-oxo-1,4-dihydroquinolin-3-yl)methyl]acetamide (6-MOQMA), by mixing with hydrogen peroxide under alkaline conditions. In the third step, the produced 6-MOQMA is concentrated, and the oxidation reagents are removed using an alkaline resistive reversed-phase column, Asahipak ODP (35 mm × 1.0 mm i.d.). In the final fourth step, the 6-MOQMA is determined by a microbore-ODS column packed with ultrafine particles (CAPCELL PAK C18 IF, 250 mm × 1.0 mm i.d.). The limit of detection of melatonin using this system is about 200 amol/injection, and the determination of endogenous melatonin in a small volume of human physiological fluids, such as 100 μL of plasma and 300 μL of saliva, was successfully accomplished.
  • Toshiaki TAZAWA, Yuuhi MORI, Akira KOBAYASHI, Kenichi NAKANE, Tomoya M ...
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1137-1141
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    A bundle of polymer-coated filaments was successfully introduced as an extraction medium for the preconcentration of an aqueous solution of aromatic compounds. The extraction was simply carried out with pumping the aqueous sample solution to the extraction capillary at ambient temperature. The extracted analytes were sequentially eluted with a flow of pure water using temperature-programmed heating of the extraction capillary in an oven. The results clearly suggest that the polymer-coated fiber-packed capillary could be employed in the sample preparation process for the analysis of various aqueous samples. Introducing the fractions eluted from the fiber-packed capillary to a conventional microcolumn liquid chromatography (micro-LC) system via a home-made valve-based modulator, an on-line coupled extraction/separation system was developed and a possibility to a pseudo-two-dimensional (pseudo-2D) LC separation of aromatic compounds in aqueous matrices has also been demonstrated.
  • Daiki GOTO, Kazuki OUCHI, Masami SHIBUKAWA, Shingo SAITO
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1143-1149
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    電子付録
    It is difficult to control the electrophoretic mobility in order to obtain high resolution among saccharides in complex samples. We report herein on a new affinity capillary electrophoresis (ACE) method for an anionic monosaccharide, N-acetylneuraminic acid (Neu5Ac), which is important in terms of pathological diagnosis, using lanthanide-hexadentate macrocyclic polyazacarboxylate complexes (Ln-NOTA) as affinity reagents. It was shown that Ln-NOTA complexes increased the anionic mobility of Neu5Ac by approximately 40% through selective complexation with Neu5Ac. The extent of change in the mobility strongly depended on the type of central metal ion of Ln-NOTA. The stability constant (K) of Lu-NOTA with Neu5Ac was determined by ACE to be log Kb = 3.62 ± 0.04, which is the highest value among artificial receptors for Neu5Ac reported so far. Using this ACE, the Neu5Ac content in a glycoprotein sample, α1-acid glycoprotein (AGP), was determined after acid hydrolysis. Complete separation between Neu5Ac and hydrolysis products was successful by controlling the mobility to determine the concentration of Neu5Ac.
  • Hideomi UMEDA, Shinya KITAGAWA, Hajime OHTANI
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1151-1154
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    In HPLC, analytes injected into a separation column broaden naturally during the separation procedure. In this paper, analyte zone sharpening of peptides was achieved in pressurized capillary electrochromatography, which is a separation method that combines capillary HPLC and capillary electrophoresis (CE), by employing dynamic pH junction for CE. When the pH of the mobile phase was altered from basic to acidic in a step gradient, the analyte peptides were focused at the basic/acidic interface with the application of voltage. The effect of both pH and pressurized flow velocity on the zone sharpening was investigated. With the proposed method, the peak height of angiotensin II, [Asn1, Val5]-angiotensin II, and angiotensin III were enhanced 12, 10, and 12 times, respectively. Selective peak zone sharpening for angiotensin II was also demonstrated.
  • Kenji SUEYOSHI, Yuto NOGAWA, Kasumi SUGAWARA, Tatsuro ENDO, Hideaki HI ...
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1155-1161
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    電子付録
    In this study, a simple and highly sensitive enzyme activity assay based on reagent-release capillary–isoelectric focusing is described. Reagent-release capillaries containing a fluorescent substrate, which produces fluorescent products possessing an isoelectric point after reaction with enzymes, provides a simple procedure. This is because it allows to spontaneously inject a sample solution into the capillary by capillary action, mixing reagents, and subsequently concentrating the fluorescent products based on isoelectric focusing. Fluorescent rhodamine 110 and its monoamide derivative, which were generated as a final product and an intermediate, respectively, were then focused and separated by reagent-release capillary–isoelectric focusing. After 30 min of enzyme reactions, two focused fluorescent bands were clearly isolated along the prepared capillaries. Employing the focused band of rhodamine 110 monoamide allowed for highly sensitive detection of enzyme activity in the 10 pg mL−1 order, while that of the conventional assay using a microplate was in the ng mL−1 order. Furthermore, arraying reagent-release capillaries of different substrates on a chip allowed for simultaneous multi-assay of enzyme activity with good sensitivity in the pg mL−1 order for each protein.
  • Akihiko ISHIDA, Mitsutaka FUJII, Takehiro FUJIMOTO, Shunsuke SASAKI, I ...
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1163-1169
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    電子付録
    A compact and lightweight liquid chromatography system is presented with overall dimensions of 26 cm width × 18 cm length × 21 cm height and weight of 2 kg. This system comprises a battery-operated compact electroosmotic pump, a manual injector, a microfluidic chip device containing a packed column and an electrochemical detector, and a USB bus-powered potentiostat. The pumping system was designed for microfluidic-based reversed-phase liquid chromatography in which an electroosmotically generated water stream pushes the mobile phase via a diaphragm for the output. The flow rate ranged from 0 to 10 μL/min and had a high degree of precision. The pumping system operated continuously for over 24 h with dry batteries. The column formed in the microfluidic device was packed with 3-μm ODS particles with a length of 30 mm and a diameter of 0.8 mm. The results presented herein demonstrate the performance of the pumping system and the column using alkylphenols, catecholamine, catechin, and amino acids.
  • Fumihiko KITAGAWA, Syo NAKAGAWARA, Isoshi NUKATSUKA, Yusuke HORI, Kenj ...
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1171-1175
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    A simple and rapid vacuum-drying modification method was applied to several neutral and charged polymers to obtain coating layers for controlling electroosmotic flow (EOF) and suppressing sample adsorption on poly(dimethyl siloxane) (PDMS)-glass hybrid microchips. In the vacuum-dried poly(vinylpyrrolidone) coating, the electroosmotic mobility (μeo) was suppressed from +2.1 to +0.88 × 10−4 cm2/V·s, and the relative standard deviation (RSD) of μeo was improved from 10.2 to 2.5% relative to the bare microchannel. Among several neutral polymers, poly(vinylalcohol) (PVA) and poly(dimethylacrylamide) coatings gave more suppressed and repeatable EOF with RSDs of less than 2.3%. The vacuum-drying method was also applicable to polyanions and polycations to provide accelerated and inversed EOF, respectively, with acceptable RSDs of less than 4.9%. In the microchip electrophoresis (MCE) analysis of bovine serum albumin (BSA) in the vacuum-dried and thermally-treated PVA coating channel, an almost symmetric peak of BSA was obtained, while in the native microchannel a significantly skewed peak was observed. The results demonstrated that the vacuum-dried polymer coatings were effective to control the EOF, and reduced the surface adsorption of proteins in MCE.
  • Yuji KAWAI, Satoshi FUJINAGA, Masahiko HASHIMOTO, Kazuhiko TSUKAGOSHI
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1177-1182
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    電子付録
    An open-tubular capillary chromatography system (tube radial distribution chromatography, TRDC) was developed using a ternary solvent (water-acetonitrile-ethyl acetate; volume ratio, 3:8:4) containing 10 mmol L−1 8-quinolinol for the separation of nitrate, chloride, and sulfate compounds of Ni(II), Al(III), and Fe(III). When a mixed solution of the Ni(II) compounds was injected into an untreated fused-silica capillary tube (90 cm × 75 μm i.d.) with a ternary solvent flow rate of 0.8 μL min−1, the compounds were eluted in the following order: [Ni(II)-(8-quinolinol)3] complex, [Ni(II)-(8-quinolinol)]-nitrate ion interaction complex, [Ni(II)-(8-quinolinol)]-chloride ion interaction complex, and [Ni(II)-(8-quinolinol)]-sulfate ion interaction complex. The elution of mixtures of the Al(III) and Fe(III) compounds showed similar trends.
  • Ronald P. MANGINELL, Curtis D. MOWRY, Adam S. PIMENTEL, Michael A. MAN ...
    原稿種別: Original Papers
    2015 年 31 巻 11 号 p. 1183-1188
    発行日: 2015/11/10
    公開日: 2015/11/10
    ジャーナル フリー
    Miniaturization of gas chromatography (GC) instrumentation enables field detection of volatile organic compounds (VOCs) for chembio-applications such as clandestine human transport and disease diagnostics. We fabricated a mesoscale pulsed discharge helium ionization detector (micro-PDHID) for integrating with our previously described mini-GC hardware. Stainless steel electrodes fabricated by photochemical etching and electroforming facilitated rapid prototyping and enabled nesting of inter-electrode insulators for self-alignment of the detector core during assembly. The prototype was ∼10 cm3 relative to >400 cm3 of a commercial PDHID, but with a comparable time to sweep a VOC peak from the detector cell (170 ms and 127 ms, respectively). Electron trajectory modeling, gas flow rate, voltage bias, and GC outlet location were optimized for improving sensitivity. Despite 40-fold miniaturization, the micro-PDHID detected 18 ng of the human emanation, 3-methyl-2-hexenoic acid with <3-fold decrease in sensitivity relative to the commercial detector. The micro-PDHID was rugged and operated for 9 months without failure.