  • Yan CHEN, Andrea D. CARROLL, Louis SCAMPAVIA, Jaromir RUZICKA
    2006 年 22 巻 1 号 p. 9-14
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A micro-reactor system with continual spectrophotometric detection has been operated in Sequential Injection lab-on-valve (SI-LOV) mode and applied to enzyme kinetics and inhibition studies, using acetylcholinesterase (AChE) and angiotensin-converting enzyme (ACE) as model systems. With the advantages of automation, real-time kinetic measurement, and thorough mixing, the SI-LOV micro-reactor system allows for the monitoring of initial reaction rates and determination of reactant concentrations in the reaction mixture, both of which are essential for the determination of kinetic constants for enzymes and inhibitors. Enzyme, substrate, and inhibitor are precisely metered by the syringe pump and delivered to a stirred micro-reactor, followed by a reference scan that establishes the baseline for the following reaction rate measurement. Michaelis constants (Km) for AChE and ACE were determined to be 0.16 mM and 0.30 mM, respectively, which are consistent with literature values. The type of inhibition (competitive, uncompetitive, or mixed), the dissociation constants for the inhibitors, and the inhibitor dose-response curves were also determined.
  • Saisunee LIAWRUANGRATH, Boonsom LIAWRUANGRATH, Surasak WATANESK, Wirat ...
    2006 年 22 巻 1 号 p. 15-19
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A rapid flow injection (FI) spectrophotometric procedure for tetracycline determination is described. It is based on the injection of a 100 µl sample solution containing tetracycline into merged streams of aluminium(III) chloride (0.01 mol l-1) and Tris-buffer in the presence of KCl (0.06 mol l-1), pH 7.0, with the same optimum flow rate of 3.2 ml min-1. A yellow Al(III)-tetracycline complex was monitored at 376 nm. The flow injection system and the experimental conditions were optimized by means of the univariate method. The procedure was applied to the determination of tetracycline in pharmaceutical preparations with a high sampling rate of at least 165 h-1. A high precision with a relative standard deviation was obtained less than 0.72 and 0.30% of 5.0 and 10 µg ml-1 (n = 11), respectively. The detection limit (3 σ) and the quantification limit (10 σ) were 0.07 and 0.72 mg l-1, respectively. There were no interference effects from traditional excipients in the dosage forms when the method was applied to pharmaceutical preparations. The matrix effect could be reduced by the standard addition method.
  • I. SÚBOVÁ, A. KHENLAMI ASSANDAS, M. CATALÁ ICARDO ...
    2006 年 22 巻 1 号 p. 21-24
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    This paper presents the analytical determination of the pesticide Asulam based on its native fluorescence. The method was optimized in either a flow injection analysis (FIA) assembly or in batch. The maximum fluorescence intensity was observed for basic pH solutions and at a λex of 258 nm and a λem of 342 nm. The influence of different empirical parameters, such as the pH, the presence of surfactants, solvent polarity or solved oxygen amount, was studied. The calibration range was fitted with a linear equation from 0.01 - 3 mg l-1 Asulam and 0.005 - 15 mg l-1 Asulam for batch and continuous-flow, respectively. The RSD for both procedures was 1.0%. After testing the influence of a large series of potential interferents, the method was applied to water samples from different locations.
  • Chunling YU, Yuhai TANG, Xiaonian HAN, Xiaohui ZHENG
    2006 年 22 巻 1 号 p. 25-28
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A rapid and sensitive chemiluminescence (CL) method using flow injection analysis was described for the determination of three catecholamines: dopamine, adrenaline and dobutamine, based on their greatly enhancing effects on the CL reaction of luminol-potassium periodate in basic solutions. Under the optimized conditions, the calibration graphs relating the increase of CL intensity to the concentration of the analytes were linear. The present method allows for the determination of dopamine, adrenaline, and dobutamine over the range of 1.0 × 10-10 - 1.0 × 10-7 g/ml. The relative standard deviations for measurements (n = 11) of dopamine, adrenaline and dobutamine were 2.9, 2.3 and 1.8% when the concentrations of three catecholamines were at 1.0 × 10-9 g/ml, respectively. The detection limits of the method were 2.0 × 10-11 g/ml dopamine, 1.0 × 10-11 g/ml adrenaline and 4.0 × 10-11 g/ml dobutamine. The method was successfully applied to the determination of three catecholamines in pharmaceutical samples and blood plasma.
  • Z. PAWLICOVÁ, J. R. ALBERT-GARCÍA, I. SAHUQUILLO, J. V. ...
    2006 年 22 巻 1 号 p. 29-34
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l-1) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples h-1 of Bromoxynil in a wide interval of concentrations, over the range 5 × 10-3 - 1 mg l-1; the detection limit was 5 × 10-3 mg l-1. The RSD (n = 24) at 0.25 mg l-1 of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation.
  • Cheng-Teng HSU, Hsieh-Hsun CHUNG, Huieh-Jing LYUU, Dong-Mung TSAI, Ann ...
    2006 年 22 巻 1 号 p. 35-38
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    An electrochemical cell coupled with disposable screen-printed electrodes (SPEs) that is specifically designed for use in flow injection analysis (FIA) is described in this study. The cell is made of foldable polyoxymethylene (acetal) thick platelets with the bottom portion consisting of a cavity track to drag the SPEs in position and the top portion having pre-drilled T-like holes to arrange the Ag/AgCl reference electrode and stainless steel inlet & outlet. An “O ring” is suitably fixed on the top of the working electrode to form a thin-layer space where the electrochemical reaction can take place. Hydrodynamic characterization was validated by using a benchmark hexacyanoferrate redox couple. The results of practical analysis of glucose in human plasma clearly demonstrate the characteristics and applicability of the proposed wall-jet electrochemical cell in FIA.
  • Shizuko HIRATA, Hideki TOSHIMITSU, Masato AIHARA
    2006 年 22 巻 1 号 p. 39-43
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    Arsenic speciation analysis in marine samples was performed using high performance liquid chromatography (HPLC) with ICP-MS detection. The separation of eight arsenic species viz. arsenite (AsIII), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenate (AsV), arsenobetaine, trimethylarsine oxide (TMAO), arsenocholine and tetramethylarsonium ion (TeMAs) was achieved on a Shiseido Capcell Pak C18 column by using an isocratic eluent (pH 3.0), in which condition AsIII and MMA were co-eluted. The entire separation was accomplished in 15 min. The detection limits for 8 arsenic species by HPLC/ICP-MS were in the range of 0.02 - 0.10 µg L-1 based on 3 σ of blank response (n = 9). The precision was calculated to be 3.1 - 7.3% (RSD) for all eight species. The method then successfully applied to several marine samples e.g., oyster, scallop, fish, and shrimps. For the extraction of arsenic species from seafood products, the low power microwave digestion was employed. The extraction efficiency was in the range of 52.9 - 112.3%. Total arsenic concentrations were analyzed by using the microwave acid digestion. The total arsenics in the certified reference materials (DORM-2 and TORT-2) were analyzed and agreed with the certified values. The concentrations of arsenics in marine samples were in the range 6.6 - 35.1 µg g-1.
  • Bahruddin SAAD, Wan Tatt WAI, Abdussalam Salhin Mohd. ALI, Muhammad Id ...
    2006 年 22 巻 1 号 p. 45-50
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A flow injection analysis (FIA) method for the determination of four residual chlorine species, namely combined available chlorine (CAC), free available chlorine (FAC), total available chlorine (TAC) and chlorite (ClO2-) was developed using a flow-through triiodide-selective electrode as a detector. An important strategy of speciation studies utilized the kinetic discrimination of reactions between the CAC and FAC with Fe2+, which was applied to the speciation of FAC, CAC and TAC. The speciation of available chlorine species and chlorite (an oxychlorine species) was achieved by using the same set-up, but using flow streams of different pH. The effects of the pH of the carrier stream, the flow rate and the sample volume were studied. The method exhibited linearity from 2.8 × 10-6 to 2.8 × 10-4 M active chlorine (expressed as OCl-) with a detection limit of 1.4 × 10-6 M. The selectivity of the method was studied by examining the minimum pH for the oxidation of iodide by other oxidants, and also by assessing the potentiometric selectivity coefficients. The proposed method was successfully applied to the determination of chlorine species in tap water, and disinfecting formulations where good agreement occurred between the proposed and standard methods were found.
  • Maria C. YEBRA-BIURRUN, Rosa M. CESPÓN-ROMERO
    2006 年 22 巻 1 号 p. 51-55
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A simple field sampling-preconcentration method for zinc determination in seawater is described. Seawater was collected in situ by pumping it through a minicolumn packed with a chelating resin (Chelite P) connected to a field flow preconcentration system (FFPS). These packed minicolumns retain the dissolved zinc, and once are loaded with the analyte, they are returned to the laboratory where they are sequentially inserted into a flow injection system for on-line zinc elution with diluted hydrochloric acid and flame atomic absorption spectrometric detection. A factorial design has been used to optimize the FFPS and the flow injection elution process. The proposed method has a linear calibration range from 0.07 to at least 9.4 µg L-1 of zinc, with a detection limit of 0.02 µg L-1 and a throughput of 26 samples h-1. Validation was carried out against certified reference water samples. This procedure has been successfully applied to the determination of Zn in seawater samples from Galicia (Spain).
  • Jia-Zhong ZHANG
    2006 年 22 巻 1 号 p. 57-60
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    Incorporation of a liquid waveguide capillary flow cell into a flow injection instrument enhances the sensitivity of flow injection analysis with spectrophotometric detection by two orders of magnitude. Nitrite determination at nM levels has been used to demonstrate the feasibility of this novel technique for trace analysis. Combining the long pathlength spectrophotometry with flow injection analysis, this technique has advantages of low detection limit, good precision and high sample throughput.
  • Shin-Ichi OHIRA, Kei TODA
    2006 年 22 巻 1 号 p. 61-65
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    Accurate liquid flow control is important in most chemical analyses. In this work, the measurement of liquid flow in microliters per minute was performed, and feedback control of the flow rate was examined. The flow sensor was arranged on a channel made in a polydimethylsiloxane (PDMS) block. The center of the channel was cooled by a miniature Peltier device, and the change in temperature balance along the channel formed by the flow was measured by two temperature sensors. Using this flow sensor, feedback flow control was examined with two pumping methods. One was the electroosmotic flow method, made by applying a high voltage (HV) between the reagent and waste reservoirs; the other was the piezo valve method, in which a micro-valve-seat was fabricated in a PDMS cavity with a silicone diaphragm. The latter was adopted for a micro gas analysis system (μGAS) for measuring atmospheric H2S and SO2. The obtained baselines were stable, and better limits of detection were obtained.
  • Terufumi FUJIWARA, Imdad U. OHAMMADZAI, Mai KOJIMA, Takahiro KUMAMARU
    2006 年 22 巻 1 号 p. 67-71
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    To eliminate the use of chlorinated hydrocarbons, we have improved the method for the flow-injection (FI) determination of iodine based on the chemiluminescence reaction of iodine with luminol in a chloroform-free reversed micellar medium of the surfactant cetyltrimethylammonium chloride (CTAC) using a mixture of 1-hexanol-cyclohexane as a bulk solvent. The FI procedure used simply involves the mixing of an iodine solution in cyclohexane with the chemiluminescent reagent solution of luminol in the reversed micellar medium of CTAC in 0.38 M 1-hexanol in cyclohexane/water (buffered with sodium carbonate). The optimum conditions for the iodine determination were evaluated and a detection limit (DL) of 0.05 ng cm-3 iodine was achieved. The calibration graph obtained was linear with a dynamic range from the DL to 10 ng cm-3 iodine. The relative standard deviations (n = 5) observed at all concentrations within the linear range were less than 2.5%. The improved FI method is rapid and equally sensitive like the original one and was found to be suitable for the determination of trace iodine.
  • Aoi MIYAMOTO, Kuniko NAKAMURA, Yoshihito OHBA, Naoya KISHIKAWA, Kenich ...
    2006 年 22 巻 1 号 p. 73-76
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A sequential injection analysis (SIA) with chemiluminescence (CL) detection was developed for the measurement of antioxidative activity against singlet oxygen (1O2). Lactoperoxidase-hydrogen peroxide-bromide ion system was used for the generation of 1O2. When a 100 mM sodium acetate buffer (pH 4.5) was used as a carrier solution, the SIA-CL system could be optimized with respect to the flow-rate of the carrier, concentration of reagents and their aspiration order. The antioxidative activity was expressed as an attenuation of luminol CL due to the quenching of 1O2 by an antioxidant. The relative standard deviations of antioxidative activity (n = 3) against 1O2 for within- and between-day analyses were ≤ 1.6% (20 µM Trolox). The system was successfully applied to the assay of antioxidative activities of various antioxidants including vitamin supplements at a rate of 10 samples within 15 min. The proposed SIA-CL system was rapid and reproducible with minimum consumption of the sample and of reagents, and thus was useful for the screening of compounds possessing antioxidative activity against 1O2.
  • Michio ZENKI, Satoru FUJIWARA, Takashi YOKOYAMA
    2006 年 22 巻 1 号 p. 77-80
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A cyclic flow injection analysis (cyclic FIA) for the repetitive determination of chemical oxygen demand (COD) was developed. The acidic KMnO4 method was carried out by adopting a single-line circulating flow system. The oxidant (KMnO4) consumed by the oxidation of organic substances was regenerated and reused repeatedly, resulting in an extreme reduction of hazardous wastes. Only 50 ml of the reagent carrier solution containing 0.2 mM KMnO4 and 1 mM HIO4 in 0.8 M H2SO4 solution was continuously circulated through the system. The KMnO4 could play two roles: acting as an oxidant of the organic substances and/or a spectrophotometric reagent. The co-existing HIO4 acted as a regenerator of KMnO4, which made it possible to recycle the system repeatedly. Under two different digestions (70 and 130°C), 50 repetitive determinations of standard sodium oxalate (6.5 mg COD L-1) and D-glucose (7.2 mg COD L-1) were skillfully carried out with a slightly decreased baseline. The analytical frequency was 30 samples per hour for COD determination. The proposed method saved consumption of the used reagents, KMnO4 and H2SO4, and thus these wastes were extremely reduced. The obtained COD values with the proposed method were co-related with those provided by the manual standard method, but were fairly low owing to the insufficient digestion step.
  • Koji HIRAKAWA, Masaaki KATAYAMA, Nobuaki SOH, Koji NAKANO, Toshihiko I ...
    2006 年 22 巻 1 号 p. 81-86
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A rapid and sensitive immunoassay for the determination of vitellogenin (Vg) is described. The method involves a sequential injection analysis (SIA) system equipped with an amperometric detector and a neodymium magnet. Magnetic beads, onto which an antigen (Vg) was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of magnetic beads in an immunoreaction cell were controlled by means of the neodymium magnet and by adjusting the flow of the carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an alkaline phosphatase (ALP) labeled anti-Vg monoclonal antibody between the fraction of Vg immobilized on the magnetic beads and Vg in the sample solution. The immobilization of Vg on the beads involved coupling an amino group moiety of Vg with the magnetic beads after activation of a carboxylate moiety on the surface of magnetic beads that had been coated with a polylactate film. The Vg-immobilized magnetic beads were introduced and trapped in the immunoreaction cell equipped with the neodymium magnet; a Vg sample solution containing an ALP labeled anti-Vg antibody at a constant concentration and a p-aminophenyl phosphate (PAPP) solution were sequentially introduced into the immunoreaction cell. The product of the enzyme reaction of PAPP with ALP on the antibody, p-aminophenol, was transported to an amperometric detector, the applied voltage of which was set at +0.2 V vs. an Ag/AgCl reference electrode. A sigmoid calibration curve was obtained when the logarithm of the concentration of Vg was plotted against the peak current of the amperometric detector using various concentrations of standard Vg sample solutions (0 - 500 ppb). The time required for the analysis is less than 15 min.
  • Shin-ichiro FUJII, Munehisa UEMATSU, Soichi YABUKI, Mitsuru ABO, Etsur ...
    2006 年 22 巻 1 号 p. 87-90
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    We developed a novel microbioassay system equipped with a gradient mixer of two solutions, and we applied the microfluidic system to an anti-cancer agent test using living animal cells on a microchip. A microchannel for the gradient mixing of two solutions and eight other microchannels for cell assay were fabricated on a poly(dimethylsiloxane) substrate using a soft-lithography method. The functions necessary for this bioassay, i.e., cell culturing, chemical stimulation, cell staining, and fluorescence determination, were integrated into the microfluidic chip. Eight gradient concentrations of the fluorescein solution, ranging from 1 to 98 µg/ml, were archived at 0.1 µl/min on a microchip. A stomach cancer cell line was cultured, and a cell viability assay was conducted using 5-Fluorouracil as an anti-cancer agent on the microchip. Cell viability changed according to the estimated concentration of the agent solution. With the microbioassay system, an anti-cancer agent test was conducted using living cells simultaneously in eight individual channels with the gradient concentration of the agent on a microchip.
  • Valeria PFAFFEN, Patricia I. ORTIZ
    2006 年 22 巻 1 号 p. 91-94
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    The electrochemical behavior and amperometric-FIA quantification of minoxidil at a glassy carbon electrode is described. The procedure is based on electrochemical oxidation at 0.800 V (vs. Ag/AgCl/NaCl(3 M) in a phosphate buffer solution. Minoxidil was determined over the range 1 × 10-7 - 1 × 10-4 M. Different analytical parameters and electrode stability were analyzed to obtain the best electrode performance. The optimal conditions were: working potentials, 0.800 V; flow rate, 0.74 mL min-1; and solution pH 7.0. This system allowed a sampling rate of 120 samples per hour without any pretreatment. The proposed method was used for minoxidil quantification in pharmaceutical preparations with satisfactory results. The accuracy of FIA-amperometric method was established by a comparison with the conventional UV determination technique using a paired t-test indicating the absence of systematic errors.
  • Nobutoshi KIBA, Ayumi KOGA, Masaki TACHIBANA, Kazue TANI, Hitoshi KOIZ ...
    2006 年 22 巻 1 号 p. 95-98
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A chemiluminometric flow injection analytical system for the quantitation of L-histidine is described. Histidine oxidase (EC 1.4.3.—) from Brevibacillus borstelensis KAIT-B-022 was immobilized on tresylated poly(vinyl alcohol) beads and packed into a stainless-steel column. The hydrogen peroxide produced was detected chemiluminometrically by a flow-through sensor containing immobilized peroxidase (EC 1.11.1.7). The maximum sample throughput was 10 h-1. The calibration graph was linear from 0.05 to 5 mM; the detection limit (signal to noise ratio = 3) was 0.01 mM. The activity of immobilized histidine oxidase reduced to 65% of the initial value after 350 injections. The system was applied to the determination of L-histidine in fish meat, such as salmon, tunny, bonito, and mackerel.
  • Qiong JIA, Tomoko MATOBA, Syouhei NISHIHAMA, Kazuharu YOSHIZUKA
    2006 年 22 巻 1 号 p. 99-103
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    A urinary glucose assay has been investigated, employing a micro flow injection analysis (μFIA) combined with a separation technique of glucose from the analyte. The adsorption part using activated alumina for the glucose in the analyte can be successively integrated onto a μFI chip. The selective adsorption-desorption of glucose in the artificial urine can progress on the adsorption part. Along with this selective preconcentration of glucose, the typical FI peak of glucose can be obtained just by feeding the sample and deionized water as an elutant sandwiched with the reagent on the carrier stream. The glucose concentration in artificial urine can be quantitatively determined with the present μFIA system, while the interference of other components coexisting in urine occurs in the case of the conventional FIA system without any separation part. The described method serves as a template for improving the selectivity for the analyte in the multi-component system.
  • Le Hoang LAM, Ken SAKAGUCHI, Hiroyuki UKEDA, Masayoshi SAWAMURA
    2006 年 22 巻 1 号 p. 105-109
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    The enzyme xanthine oxidase (XOD) has been recognized as a key enzyme causing oxidative injury to tissues by ischemia-reperfusion. For this reason, XOD inhibitor, which effectively suppresses this enzyme, plays an important role in the inhibition of many diseases related to reactive oxygen species (ROS). In order to screen XOD inhibitors rapidly and conveniently, a novel assay using flow injection analysis (FIA) was proposed in the present investigation. To optimize the practical FIA system, we studied the effect of the reagent concentrations and the flow condition on the enzymatic reaction, and then selected the optimum condition as follows: 200-mU/ml XOD concentration, 0.5-mM xanthine concentration, 0.5-ml/min flow rate, and 2-m mixing coil length. Under this condition, a typical XOD inhibitor quercetin was determined in the concentration range 0.1 - 1.5 mM at a sampling frequency of 10 samples/h. Using the optimized FIA method, we determined the XOD inhibitory activity of some food samples: onions, apples and teas, which are the high sources of flavonoids known as the potential XOD inhibitors. Among these samples, tea leaves showed the highest activity, the second was onions and the lowest was apples. Based on the result of the assay, not only quercetin, but also other components in investigated samples, contributed to the XOD inhibitory activity.
  • Passapol NGAMUKOT, Thiraporn CHAROENRAKS, Orawon CHAILAPAKUL, Shoji MO ...
    2006 年 22 巻 1 号 p. 111-116
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    An electrooxidation and a cost-effective flow-based analysis of malachite green (MG) and leucomalachite green (LMG) were investigated at a boron-doped diamond thin-film (BDD) electrode. Cyclic voltammetry as a function of the pH of the supporting electrolyte solution was studied. Comparison experiments were performed with a glassy carbon electrode. A well-defined cyclic voltammogram, providing the highest peak current, was obtained when using phosphate buffer at pH 2. The potential sweep-rate dependence of MG and LMG oxidation (peak currents for 1 mM MG and LMG linearly proportional to v1/2, within the range of 0.01 to 0.3 V/s) indicates that the oxidation current is a diffusion-controlled process on the BDD surface. In addition, hydrodynamic voltammetry and amperometric detection using the BDD electrode combined with a flow injection analysis system was also studied. A homemade flow cell was used, and the results were compared with a commercial flow cell. A detection potential of 0.85 V was selected when using a commercial flow cell, at which MG and LMG exhibited the highest signal-to-background ratios. For the homemade flow cell, a detection potential of 1.1 V was chosen because MG and LMG exhibited a steady response. The flow analysis results showed linear concentration ranges of 1 - 100 µM and 4 - 80 µM for MG and LMG, respectively. The detection limit for both compounds was 50 nM.
  • Mikaru IKEDO, Masanobu MORI, Kazumasa KURACHI, Wenzhi HU, Kazuhiko TAN ...
    2006 年 22 巻 1 号 p. 117-121
    発行日: 2006年
    公開日: 2006/02/24
    ジャーナル フリー
    The selective and simultaneous ion-exclusion chromatography (IEC) with UV-detection on a weakly acidic cation-exchange resin column in the H+-form (TSKgel Super IC-A/C) was developed and applied for the simultaneous determination of phosphate and silicate ions as the water quality parameters required for optimizing the water-leaching process for ceramics glaze raw materials of natural origin including feldspar, woods-ash, and straw-ash. Phosphate and silicate ions in these water-leaching process water samples were separated selectively from the coexisting anions such as sulfate, chloride, nitrate and carbonate ions, based on the ion-exclusion separation mechanism. They were detected selectively and simultaneously by a postcolumn derivatization with molybdenum-yellow using the UV-detector. Under the optimized separation and detection conditions (eluent, 0 - 1 mM sulfuric acid; reactant, 10 mM sodium molybdate-25 mM sulfuric acid; detector, UV at 370 nm; temperature, 45°C), the linearity of calibration was in the range 0.1 - 10 ppm for both phosphate and silicate ions, and the detection limits at S/N = 3 were 2.58 ppb for silicate ions and 4.75 ppb for phosphate ions. The effectiveness of this method was demonstrated in practical applications to the water-leaching process for some ceramics glaze raw materials.