    The aim of this study was to assess the association between perinatal status and insulin resistance in neonates during the birth period. The subjects were 49 neonates (27 boys, 22 girls) who had been admitted to the neonatal intensive care unit at Nihon University Itabashi Hospital within 2 h after birth. We retrospectively analyzed the associations between perinatal status (Apgar score, sex, gestational age, birth weight, etc.) and insulin resistance (assessed by plasma immunoreactive insulin (IRI), plasma cortisol, homeostatic model analysis ratio (HOMA-R), quantitative insulin sensitivity check index (QUICKI), plasma glucose/IRI ratio, and plasma IRI/cortisol ratio) based on the medical records. The preterm neonates had significantly lower plasma cortisol levels (P = 0.02) and significantly higher plasma IRI/cortisol ratios (P = 0.04) compared with the full-term neonates. No significant differences were found in any of the parameters between neonates with asphyxia and those without. In cases with hyperinsulinemia, male predominance was significant (P < 0.01) in neonates with hypoglycemia; furthermore, birth weight, HOMA-R, and plasma glucose/IRI ratio tended to be lower (P = 0.07, P = 0.01 and P < 0.01, respectively), while QUICKI and plasma IRI/cortisol ratio tended to be higher (P = 0.02 and P = 0.09, respectively) in neonates with hypoglycemia compared with those without. One possible reason for these findings could be the immaturity of the hypothalamic-pituitary-adrenal axis in preterm infants. There was no significant correlation between perinatal status and the indices of insulin resistance in neonates during the birth period.
  • 石本 真一郎, 村松 高, 四万村 三恵, 古市 基彦, 竹下 伸二, 田中 洋子, 諸岡 宏明, 日暮 亮太, 元美 塩野
    2016 年 75 巻 5 号 p. 219-222
    発行日: 2016/10/01
    公開日: 2016/11/07
    ジャーナル フリー
    自動縫合器で切離した気管支断端部の耐圧がどのくらいあるのかを切除肺を利用して検討した.対象は自動縫合器を用いて気管支処理をした20 症例.自動縫合器は2 種類(Echelon® のグリーンカートリッジとEndoGIA® のパープルカートリッジ)使用し,各10 例ずつとした.方法は水没状態にした切除肺の気管支断端に18 G のサーフロ針を挿入し,マンシェットによる加圧を行うことで測定した.結果は平均圧は Echelon® が112.5 cmH2O,EndoGIA® が113.5 cmH2O であった.両者の耐圧に統計学的な有意差を認めなかった.通常,気道内圧は20-30 cmH2O(呼気時)であることを考慮すると,十分な耐圧が示された.一方で,縫合に比べて自動縫合器の方が,気管支断端瘻の発生率が高かったとの報告も散見される.自動縫合器では術者の手加減で自在に締め具合を調節できず,症例毎の適切なstapler の選択やstapling 前の気管支の圧挫も念頭に置くべきである.
症例報告
話題
feedback
Top