  • Aiki Watanabe, Asuka Haga, Takefumi Minakawa, Masaaki Ikeda, Naoshi Hi ...
    2022 Volume 142 Issue 9 Pages 368-374
    Published: September 01, 2022
    Released on J-STAGE: September 01, 2022
    JOURNAL RESTRICTED ACCESS

    The insulation performance of cables removed from an actual plant was investigated in a simulated severe accident (SA) environment. The cable insulated with flame-retardant ethylene propylene diene rubber (FR-EPDM) was a safety cable in the plant. A similar FR-EPDM-insulated cable was aged artificially to the degree equivalent to what the removed cable would have been suffered. These cables were irradiated with 60Co gamma rays at a dose rate of 10 kGy/h for 50 hours at room temperature to simulate the radiation exposure during a SA. The cables were then exposed to a steam environment for 168 hours to simulate the SA. During the steam exposure, the insulation resistance of the cables was measured continuously. As a result, the minimum insulation resistance was about 108 to 109 Ωm in the two cables, indicating that both have sufficient insulation performance.

    Download PDF (1825K)
  • Hironori Yanase, Hiroshi Mitsudome, Kenji Okamoto, Masahiro Kozako, Ma ...
    2022 Volume 142 Issue 9 Pages 375-380
    Published: September 01, 2022
    Released on J-STAGE: September 01, 2022
    JOURNAL RESTRICTED ACCESS

    This paper presents the effect of impulse voltage prestress on AC partial discharge characteristics of laminated PET films including an artificial void. The results of AC partial discharge (PD) tests shows that PD inception voltage (PDIV) largely drops after the impulse prestress irrespective of the void diameter and gap length, and later recovers to the first PDIV measured before the prestress. An attempt is made to estimate quantitatively the charge density accumulated on the void surface after the impulse voltage application causing PD from a difference in PDIV before and after the prestress. The observed effect of the prestress on the decrease and recovery of PDIV is discussed in terms of the accumulated surface charge behavior.

    Download PDF (1096K)
Special Issue Letter
Paper
  • Yuhei Ozawa, Naoki Morikawa, Kunihisa Tashiro, Hiroyuki Wakiwaka, Tsut ...
    2022 Volume 142 Issue 9 Pages 383-389
    Published: September 01, 2022
    Released on J-STAGE: September 01, 2022
    JOURNAL RESTRICTED ACCESS

    In this report, the magnetic dipole moment was used to determine the need for a magnetic shield for capsule endoscopy guiding device. In addition, the index of the number of layers of MSC was examined from the evaluation of the magnetic shield characteristics of the open pail can, which is attracting attention as MSC, and the magnetic dipole moment. As a result, it became clear that the magnetic guiding device needs to be magnetically shielded at 11 Am2 and above. In addition, when the shielding performance of the open pail can was evaluated, it was shown by analysis that the magnetic flux density could be reduced by up to 1.53 mT and the relative permeability was 1000. Finally, it was found that when the magnetic dipole moment of the magnetic inducer is less than 41 Am2, only the open pail can is required, and when it is 41 Am2 or more, the MSC needs to have two or more layers.

    Download PDF (1248K)
  • Masaki Takeuchi, Yutaro Soejima, Jaesol Ahn, Kunhak Lee, Ken Takaki, T ...
    2022 Volume 142 Issue 9 Pages 390-396
    Published: September 01, 2022
    Released on J-STAGE: September 01, 2022
    JOURNAL RESTRICTED ACCESS

    The Conventional electrolarynx (EL) restores the voice of people who have lost their voice, however, its voice sounds like a robot and it occupies user's one hand. Therefore, we developed a hands free wearable electrolarynx that improves the voice quality with the LPC residual wave as the vibration sound. Our device outputs the voice with a clearer formant on F3 and F4 than conventional EL does. Thus, we verified that the individuality of the voice can be expressed with our device.