The purpose of this study is to look into applicability of Ultra-Violet (UV) to sterilizing the surface of sausage. At first, stenlizing effect of UV was examined in regard to the suspension of E. coli and B. subtilis spores. In the next, sterilizing effect on the surface of wiener sausage was examined by an UV sterilizing device which was made on an laboratory scale. (1) In the suspension of bacteria, irradiation time of UV required to destroy E. coli from the level of 10
7 to 10
0 was around 13 seconds for 2mW/cmcm
2, and around 2 seconds for 60mW/cmcm
2. In deStroying B. subtilis spores from 10
6 to 10
0, the time was around 120 seconds and 5 seconds each. (2) In the experiment by wiener sausage, UV-lamp with high intensity more than 40mW/cmcm
2, being irradiated for five seconds, sterilized bacteria adhered to the surface of sausage to the level of less than 5. This result was obtained in regard to E. coli (10
5 per sausage) as well as B. subtilis spores (10
4 per sausage). (3) Sterilizing effect at the edges of sausage was inferior to the surface of sausage. This fact was, we considered, caused by shadows at the edges made by ray of the lamp.
View full abstract