In the case of the sensorless control for the PMSM that estimates position and velocity from EMF using the model of a synchronous motor with the voltage and current, it is desirable for voltage and current to be perfect sine waves. However, in fact, various harmonic components are contained in the voltage and current, and they have bad influence on the estimation performance of a sensorless control.
In this paper, we propose a improving method of sensorless control performance for the IPMSM by suppression of harmonic component in current control loop of the vector control using Fourier transform and repetitive control. To suppress harmonic components, compensation signals are acquired using Fourier transform and repetitive control, and feedforward control is implemented with the acquired compensation signals.
To evaluate our proposed system, the sensorless control system for the IPMSM is taken for instance. The system is constructed on the basis of the extended EMF disturbance observer with the current and voltage command whose harmonic components are suppressed. As a result, we can have a margin in the pole assignment of disturbance observer, and the performance of sensorless control can be improved. The effectiveness of the proposed method is confirmed by experimental results.
抄録全体を表示