レーザー研究
Online ISSN : 1349-6603
Print ISSN : 0387-0200
ISSN-L : 0387-0200
32 巻, 2 号
選択された号の論文の12件中1~12を表示しています
レーザー解説
レーザーオリジナル
  • Haik CHOSROWJAN, Noboru MATAGA, Seiji TANIGUCHI, Masashi UNNO, Hironar ...
    2004 年32 巻2 号 p. 114-120
    発行日: 2004年
    公開日: 2008/01/21
    ジャーナル フリー
    Low frequency vibrations of the native PYP and related systems in solution have been investigated in "time" (fs fluorescence up-conversion) and "frequency" (resonance Raman) domains to elucidate their role in ultrafast photoisomerization reaction dynamics of PYP. Tentative assignments of the oscillatory components to particular vibrations are proposed supported by normal mode calculations based on DFT and ab initio MO methods. It is concluded that the out-of-plane skeleton bending mode of the chromophore, γ16, is responsible for the observed oscillations in native and all mutant PYPs (f1 ∼ 135 cm-1), while in-plane ν'42 and ν'43 modes are probably responsible for oscillations observed in the PYP analogue with locked chromophore. A dynamic model called "trigger mode mediated guidance" has been proposed to explain in simple terms the ultrafast primary process initiating PYP's photocycle. Furthermore, first successful fluorescence dynamics experiments on PYP single crystals with femtosecond time resolution are presented and discussed.
  • 尾園 和恵, 萩原 寛浩, 小原 實
    2004 年32 巻2 号 p. 121-125
    発行日: 2004年
    公開日: 2008/01/21
    ジャーナル フリー
    The micromachining of hydroxyapatite (HAp) and collagen is highly required for orthopedics and dentistry, because human bone and tooth consist mainly of HAp oriented along the collagen. We have evaluated ultrashort Ti:sapphire laser ablation of HAp and collagen with pulsewidth of 50 fs - 2 ps at 820 nm and 1 kpps. The crucial medical issue is to preserve the chemical property of the ablated surface. If chemical properties of HAp and collagen change once, the human bone or tooth cannot re-grow after laser processing. Using x-ray photoelectron spectroscopy we have observed chemical properties of the HAp ablated in air. As a result it is found that the ablated surface is unchanged after laser ablation over the pulsewidth range used in this experiment. Human tooth enamel is precisely ablated with 60 fs and 2 ps laser pulses. Collagen is also found to preserve the initial infrared properties during 160 fs laser ablation.
  • 吉川 秀樹, 菅本 一臣
    2004 年32 巻2 号 p. 126-130
    発行日: 2004年
    公開日: 2008/01/21
    ジャーナル フリー
    The bonding between a metal surface of a human joint prosthesis and a bone is not perfect. It makes the loosening of a metal component from a bone. Porous coating method is widely used to have a rough metal surface, but it cannot regulate the shape of a metal surface. It cannot make enough bonding. Our method is a new metal processing method using a laser scanning for a joint prosthesis, which was developed in Osaka Univ. Graduate School. The metal surface with a microscopic canal structure, which was processed by a new method, has a few times bonding strength compared to a porous coated surface. A new bone invasion was observed in all cavities of the canals. The results encourage the development of a new joint prosthesis which has no loosening from a bone.
レーザーオリジナル
feedback
Top