As a burner for boiler equipped on the L.N.G. carrier, the gas/oil combined burners having some special performances are needed in respect of the operating conditions.
The firing test was carried out by use of Chugai Ro-Hamworthy HXG burner which has been developed for a long period of time in order to be furnished with the above-mentioned special performances.
Burner performances investigated in the test are as follows:
1) Minimum excess air ratio.
2) Variations of flame length against gas-oil firing ratio.
3) Stability of oil flame under such burner operating conditions as ignition and shutting-off of fuel gas.
4) Relation between the blowing volume of N
2gas and stability of flame.
5) Temperature of gas nozzle tip under each operating condition.
6) Variations of register draught loss against gas-oil firing ratio.
The results of the test are shown concretely on the tables and figures for the convenience of designing the combustion equipment for L.N.G. carrier.