分光研究
Online ISSN : 1884-6785
Print ISSN : 0038-7002
ISSN-L : 0038-7002
18 巻, 4 号
選択された号の論文の4件中1~4を表示しています
  • 末高 治
    1969 年 18 巻 4 号 p. 187-193
    発行日: 1969/09/30
    公開日: 2011/02/23
    ジャーナル フリー
  • 大井 尚文
    1969 年 18 巻 4 号 p. 194-201
    発行日: 1969/09/30
    公開日: 2010/06/28
    ジャーナル フリー
  • 13%Mn鋼, 18%Mn-5%Cr鋼
    前川 静弥, 鈴木 孝範, 森永 博
    1969 年 18 巻 4 号 p. 202-209
    発行日: 1969/09/30
    公開日: 2010/06/28
    ジャーナル フリー
    In order to raise the efficiency of analytical works for a high alloy steel (13% Mn steel, 18% Mn-5% Cr steel) by means of a quantorecorder, a study of quantitative analysis was made for samples obtained from molten steel in the smelting furnace, and samples from final products.The results obtained are summarized as follows:
    (1) Cr 2677.16A line is affected by Mn 2677.24A or 2676.74A line and Si 2516.12A line is affected by Mn 2516.73A line in the case of oscillatory low voltage spark, and, therefore, some correction should be made.
    (2) Analytical results obtained by the present method was satisfactory for samples in the steel-smelting process.For pit samples and samples from products, however, conventional chemical analysis should be employed.
  • (第1報) 測定装置および酸化ランタン中の希土類元素の定量
    中島 篤之助, 河口 広司, 高島 教一郎, 大内 義彦
    1969 年 18 巻 4 号 p. 210-217
    発行日: 1969/09/30
    公開日: 2011/02/23
    ジャーナル フリー
    A rapid, quantitative analytical technique for the analysis of rare earth impurities is described.The method, X-ray excited optical fluorescence, uses high-energy X-rays to excite the rare earth impu-rities in appropriate matrices.The excited rare earth impurities fluorescence with simple line emission spectra which can be used for quantitative measurements.
    The experimental equipment employed is similar to that described by Linares et al. and also Sasaki.In the present study the X-ray source is a Machlett OEG-60 tungsten-target X-ray tube driven by a ARL power supply.A sample chamber is shown in Fig.2.The fluorescent radiation is made monochromatic by a Hitachi Perkin-Elmer Model 139 scanning spectrophotometer equipped with a 1440 lines/mm grating blazed at 2000Å, and detected with an photomuitiplier (HAMAMATSU TV Co., Ltd.R106) having S-19 response, and a fused silica-envelope.An amplifier equipped in the spectrophoto-meter and a chart recorder (TOA Electronics Ltd., EPR-2T) complete the system.
    Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er and Tm have been determined by this method with detection limits ranging from 0.2 ppm to 20 ppm in La2O3.
    Appreciable amounts of Pr, exceeding 500 ppm in some cases was found in commercial La2O3, which had been used as the raw material for optical glass.
    Spectrum patterns obtained for each rare earth element in La2O3 are also presented.The detection limits in other oxide systems are surveyed and discussed.