23 巻 , 1 号
選択された号の論文の8件中1~8を表示しています
  • 1994 年 23 巻 1 号 p. 1-7
    発行日: 1994/03/31
    公開日: 2012/11/27
    ジャーナル フリー
    For sensitive measurement of the anti-thyroglobulin antibody in serum, a two-step sandwich chemiluminescence enzyme immunoassay (CLEIA) was developed. This method uses a microplate as a solid phase, peroxidase as a labeling enzyme, and luminol and an enhancer as chemiluminescence reagents. The CLEIA allowed absolute levels of the antibody to be measured over a wide range (from 100 to 100,000 ng/ml). The results of this assay correlated with those from a dual antibody radioimmunoassay (RIA) 1), revealed a correlation coefficient of 0.64 and regression equation of Y=21.6X-160 (N=20). There was poor agreement between the results from the two assays at high concentrations. The upper limit of the normal range for blood anti-thyroglobulin antibody was 195 ng/ml. Antibody levels significantly lower than this concentration were found to cause underestimation of serum thyroglobulin levels. Serum anti-thyroglobulin antibody levels were determined for 30 patients who had been checked periodically for serum thyroglobulin after surgical resection of thyroid cancer. Levels higher than 200 ng/ml were found for 6 of these patients. In these cases, the serum thyroglobulin levels seemed to be underestimated because of the presence of high levels of anti-thyroglobulin antibody. These findings indicate the necessity of measurement of the levels of both anti-thyroglobulin antibody and thyroglobulin for early detection of recurrence after surgical resection of thyroid cancer.
  • 1994 年 23 巻 1 号 p. 8-14
    発行日: 1994年
    公開日: 2012/11/27
    ジャーナル フリー
    A chemiluminescent enzyme immunoassay (CLEIA) was developed for measurina thyroglobulin in serum. This assay is rapid, easy to perform, and highly sensitive. A microplate was used as the solid phase, peroxidase as the labeling enzyme, and luminol and enhancer as the chemiluminescence reagents. The minimum concentration of thyroglobulin detectable by this CLEIA was 0.05 ng/ml. The results obtained with the CLEIA were in good agreement with those obtained by the standard RIA, the correlation coefficients being r=0.98, Y=0.97X-5.1. where Y is the CLEIA value and X the RIA value. The CLEIA was used to measure thyroglobulin serum levels as a means to monitor thyroid cancer. In most patients, the high preoperative levels dropped to nearly 0 ng/ml after total thyroidectomy, and then increased again upon recurrence. In conclusion, measurement of the thyroglobulin serum level changes by this highly sensitive assay is effective for early discovery of thyroid cancer recurrence postoperatively.
  • , , ,
    1994 年 23 巻 1 号 p. 15-20
    発行日: 1994年
    公開日: 2012/11/27
    ジャーナル フリー
    The effects of treatment with valproic acid (VPA) and other anticonvulsants such as phenobarbital, phenytoin, and carbamazepine on serum carnitine levels were studied. Considering the influence of gender and age on the reference intervals of serum carnitine levels, the levels in patients receiving anticonvulsant therapy (>10 years old) were compared with those in gender-matched controls. VPA therapy alone reduced the serum free carnitine (FC) levels in both male and female groups. Moreover, VPA polytherapy caused marked decrease of serum FC levels and increased the incidence of hypocarnitinemia. The non-VPA anticonvulsant therapies also reduced serum FC levels, however, the incidence of hypocarnitinemia was unchanged in the non-VPA polytherapy groups.
  • ,
    1994 年 23 巻 1 号 p. 21-25
    発行日: 1994/03/31
    公開日: 2012/11/27
    ジャーナル フリー
    We described the diazo reaction of bilirubins IIIα, IXα and X IIIα, using various diazonium salts. These bilirubin isomers reacted with diazonium salts to form an azo dye with a slightly different absorption peak. There was little difference in the rate constant between these three isomers, while a significant difference in the color intensity of the azo dyes was observed. It has been reported that serum bilirubin in human adults is bilirubin IXα, but in patients' sera after storage bilirubins IIIα and X IIIα were also detected by means of thin layer chromatography. The relative proportions of formation of these three isomers were correlated with serum total bilirubin concentration.
  • 畠 啓視, 徳廣 寿子, 三浦 雅一
    1994 年 23 巻 1 号 p. 26-31
    発行日: 1994/03/31
    公開日: 2012/11/27
    ジャーナル フリー
    われわれはポリアクリルアミドディスクゲル電気泳動分析後, デンシトメトリーで測定を行う骨型ALPの精密測定の検討を行った。本法の同時再現性は2%以内で, 20mU/mlまで測定が可能であった。セルロースアセテート膜 (CA) 電気泳動法との相関も良好であったが, 本法ではCA電気泳動法よりも肝臓と骨型ALPの分離が明瞭となるため, デンシトメーターで測定するとCA法よりも骨型ALPが正確に検出されることがわかった。さらに, 男女68例の基準範囲を求めたところ, 53±36.6mU/mlであった。この結果は先に報告した小麦胚芽レクチンを用いた親和性電気泳動法の結果に類似していた。骨型ALPの精密測定は骨疾患での骨代謝マーカーとして有用であると思われた。
  • 三浦 雅一, 宇治 義則, 畠 啓視, 岡部 紘明
    1994 年 23 巻 1 号 p. 32-37
    発行日: 1994/03/31
    公開日: 2012/11/27
    ジャーナル フリー
    われわれはキャピラリー電気泳動 (CE) でヒト血清蛋白の分析を試みた。キャピラリーカラムは未処理フユーズドシリカキャピラリー20μm (i.d.)×有効長20cmを使用した。検出波長は200nmで, 泳動温度は23℃ で行った。ヒト血清試料を20mM PBS (pH10.0) で11倍に希釈した試料を10秒間圧挿入した後, 電解液として150mMホウ酸緩衝液 (pH10.0) を用い, 6.5分間電気泳動を行った。ヒト血清試料は5分画に分離され, セルロースアセテート膜電気泳動での分画と同一パターンを示した。また, CEでは血清試料を10ピークに分離することができた。これらのピークはmigration timeの速いピークより免疫グロブリン, C3, トランスフェリン, α2マクログロブリン, ハプトグロビン, α1アンチトリプシン, アルブミン, プレアルブミンの蛋白成分であることが同定された。さらに, 各種疾患でのCEの泳動パターンはセルロースアセテート膜電気泳動での結果と類似していた。これらの結果より, CEシステムは臨床診断に有用な手法であり, 今後日常検査に利用できるものと思われる.
  • 1994 年 23 巻 1 号 p. 38-
    発行日: 1994年
    公開日: 2012/12/14
    ジャーナル フリー
  • 1994 年 23 巻 1 号 p. 39-47
    発行日: 1994/03/31
    公開日: 2012/11/27
    ジャーナル フリー