Neurologia medico-chirurgica
Online ISSN : 1349-8029
Print ISSN : 0470-8105
ISSN-L : 0470-8105
Volume 58, Issue 5
Displaying 1-8 of 8 articles from this issue
Original Articles
  • Yoshiro ITO, Wataro TSURUTA, Yasunobu NAKAI, Tomoji TAKIGAWA, Aiki MAR ...
    2018 Volume 58 Issue 5 Pages 191-198
    Published: 2018
    Released on J-STAGE: May 15, 2018
    Advance online publication: March 03, 2018
    JOURNAL OPEN ACCESS

    Carotid endarterectomy (CEA) and carotid artery stenting (CAS) are not appropriate treatment procedure for internal carotid artery stenosis (ICAS) in some patients. The importance of plaque vulnerability and the treatment risk evaluation has been reported. We analyzed whether treatment selection contributes to the outcome. We retrospectively examined 121 patients who underwent CEA or CAS. Treatment was selected based on plaque vulnerability and the treatment risk evaluation. We selected CAS for patients with stable plaques and CEA for patients with unstable plaques, and considered the other treatment for high-risk patients. The patients were classified as the stable plaque (Stable: n = 42), the unstable plaque and CEA low risk (Unstable/Low: n = 30), and the CEA high-risk (Unstable/High: n = 49). Frequency of perioperative stroke, myocardial infarction, death, and systemic complications was examined. CEA and CAS were performed in 35 and 86 patients, respectively. One patient (2.9%) had a stroke in CEA and five patients (5.8%) in CAS (P = 0.50). Systemic complications were observed in two patients (5.7%) in CEA and six (7.1%) in CAS (P = 0.80). There were no differences in stroke (Stable; 2.4%, Unstable/Low; 3.2%, and Unstable/High; 8.2%) and systemic complications (Stable; 9.5%, Unstable/Low; 3.3%, and Unstable/High; 6.1%) among three groups (P = 0.44 and P = 0.59, respectively). The treatment selection based on plaque vulnerability and the treatment risk evaluation could provide good treatment outcome for high-risk patients. It is ideal to select an appropriate treatment for ICAS by one neurovascular team.

    Download PDF (833K)
  • Tatsuya SASAKI, Takashi AGARI, Ken KUWAHARA, Ittetsu KIN, Mihoko OKAZA ...
    2018 Volume 58 Issue 5 Pages 199-205
    Published: 2018
    Released on J-STAGE: May 15, 2018
    Advance online publication: May 01, 2018
    JOURNAL OPEN ACCESS

    The success of deep brain stimulation (DBS) depends heavily on surgical accuracy, and brain shift is recognized as a significant factor influencing accuracy. We investigated the factors associated with surgical accuracy and showed the effectiveness of a dural sealant system for preventing brain shift in 32 consecutive cases receiving DBS. Thirty-two patients receiving DBS between March 2014 and May 2015 were included in this study. We employed conventional burr hole techniques for the first 18 cases (Group I) and a dural sealant system (DuraSeal) for the subsequent 14 cases (Group II). We measured gaps between the actual positions of electrodes and the predetermined target positions. We then retrospectively evaluated the factors involved in surgical accuracy. The average gap between an electrode’s actual and target positions was 1.55 ± 0.83 mm in all cases. Postoperative subdural air volume e, the only factor associated with surgical accuracy (r = 0.536, P < 0.0001), was significantly smaller in Group II (Group I: 43.9 ± 27.7, Group II: 12.1 ± 12.5 ml, P = 0.0006). The average electrode position gap was also significantly smaller in Group II (Group I: 1.77 ± 0.91, Group II: 1.27 ± 0.59 mm, P = 0.035). Use of a dural sealant system could significantly reduce intracranial air volume, which should improve surgical accuracy.

    Download PDF (1075K)
  • Takashi ASAHI, Michi SATO, Takuto NAKAMURA, Yuki KON, Hiroyuki KAJIMOT ...
    2018 Volume 58 Issue 5 Pages 206-211
    Published: 2018
    Released on J-STAGE: May 15, 2018
    Advance online publication: March 31, 2018
    JOURNAL OPEN ACCESS

    The hanger reflex (HR) is an involuntary head rotation that occurs in response to a clothes hanger encircling the head and compressing the unilateral fronto-temporal area. Here, we developed an elliptical device to induce the HR and examined its utility for the treatment of cervical dystonia (CD). The study included 19 patients with rotational-type CD. The device was applied to each subject’s head for at least 30 min/day for 3 months. Severity scores on part 1 of the Toronto Western Spasmodic Torticollis Rating Scale were evaluated at baseline and after the 3-month trial. Mean scores without and with the device were significantly different both at baseline (16.6 vs. 14.7, respectively; P < 0.05) and after the trial (14.9 vs. 13.6, respectively; P < 0.05). This preliminary trial suggests that our device can improve abnormal head rotation in patients with CD.

    Download PDF (513K)
  • Takashi YAGI, Toru HORIKOSHI, Nobuo SENBOKUYA, Hiroaki MURAYAMA, Hiroy ...
    2018 Volume 58 Issue 5 Pages 212-218
    Published: 2018
    Released on J-STAGE: May 15, 2018
    Advance online publication: May 01, 2018
    JOURNAL OPEN ACCESS

    The aim of this study is to clarify the details of distribution patterns of spinal epidural fluid and to establish it as measure of spontaneous intracranial hypotension (SIH) syndrome diagnosis. Magnetic resonance imaging findings of the spine were analyzed in 37 patients, 24 women and 13 men (mean age 46.3 years), with SIH. Detection rate, thickness and patterns of the fluid collection were evaluated at every vertebral level. Follow-up spinal MRI findings were also analyzed for changes in epidural fluid collection and association with clinical symptoms. The MR images of the cervical spine were obtained in 30 patients, the thoracic spine in 36, and the lumbar spine in 17 patients. Epidural fluid collection was detected totally in 36 patients (97%) and was predominantly found at the mid-thoracic vertebrae. The fluid tended to locate dorsal to the dural sac at the thoracic spine and ventral at the cervical and lumbar spine. Patients with shorter duration of illness tended to have thicker fluid in the thoracic spine. In follow-up MRI, the findings of epidural fluid collection has disappeared in 32/36 cases within 3 months after treatment. Although residual fluid collection was found at the thoracic level in 4 cases, clinical symptoms were improved in all patients. This study suggested that the mid-thoracic spine should be chosen as the target of MRI in screening of SIH, and enlarged dorsal epidural space is strongly indicative of SIH.

    Download PDF (809K)
Case Report
  • Shigeru MIYACHI, Hiroyuki OHNISHI, Ryo HIRAMATSU, Ryokichi YAGI, Toshi ...
    2018 Volume 58 Issue 5 Pages 219-224
    Published: 2018
    Released on J-STAGE: May 15, 2018
    Advance online publication: May 01, 2018
    JOURNAL OPEN ACCESS

    A 48-year-old female with a symptomatic giant carotid cavernous aneurysm underwent endovascular treatment with multiple Pipeline Flex embolic devices (PED). The delivery catheter had to take a complicated course of multiple turns to cross the aneurysm, and its loop was tied in the aneurysm. When the catheter was to be withdrawn, it was apparent that the tied catheter had made a tight knot that bound the tail of the previous PED together. We successfully retrieved all of the system including the tied PED, and we used telescoping stents with five PEDs in the next operation. Although this is a rare complication, it is worth noting and checking to make sure that there is no knot before deploying the stent.

    Download PDF (653K)
Rapid Communication
ERRATUM
Editorial Committee
feedback
Top