In the present paper experimental studes on driect electric curing is reported continuously in part I of this paper. Experimental studies was carried out with experimentatic programing L_18 (2^1+3^7) type on the subject of the reasonable specification about extractation of water and its the necessary time from concrete, temperature of concrete, and economy on a cut of electric power consumption. Reasonable specification on electric curing of concrete was decided by result of each work. Experimental primary factor are kind of aggregates (natural aggregate, natural light weight aggregate artificial light weight aggregate), kind of cements (portland cement, silica cement, portland blast furnace cement), activity agent (vinsol, pozzolis), sand aggregate ratio (35, 40, 45), volume of cement (230, 250, 270kg/m^3), volume of water (150, 170, 190l/m^3), and electric current (1A, 2A, 3A). Result of work, effect of current have the most favorable influence on it. Resonable specification on electric curing of concrete is such that; concrete is produced by portland blast furnace cement and its proportion is 210〜230kg/m^3. Proportion of water is 190l/m^3 and of sand aggregate ratio is 35〜45 percentage. Electric current is 1A (0.1 A/cm, 0.025 A/cm^2). Ion is educed from cathode plate by direct electric current. Volume of educe is calibrated by Faradey's Law. 6g of lead per 1g equivalence is educe. Chemical constituent of cohesion is shown table 4.