Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Volume 24, Issue 6
Displaying 1-26 of 26 articles from this issue
Rapid Communications
  • Chunxia ZHAO, Arivazhagan RAJENDRAN, Qing DAI, Seiichi NISHIZAWA, Nori ...
    2008 Volume 24 Issue 6 Pages 693-695
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A fluorescent pyrazine derivative, 3,5-diamino-6-chloro-2-pyrazine carbonitrile (DCPC), is presented as a promising light-up ligand for single-nucleotide polymorphisms (SNPs) typing. In solutions buffered to pH 7.0 (I = 0.11 M, at 5°C), DCPC can bind to thymine selectively over other nucleobases opposite an abasic site in DNA duplexes (5′-GTGTG CGTTG ANA TGGAC GCAGA-3′/3′-CACAC GCAAC TXT ACCTG CGTCT-5′, X = abasic site, N = target nucleotide) with a dissociation constant of 2.6 µM. The binding of DCPC is accompanied by a significant enhancement of its fluorescence (λmax, 412 nm), and the response is highly selective to thymine base. These binding and sensing properties allow a clear detection of thymine-related mutations present in polymerase chain reaction (PCR) amplification products.
    Download PDF (555K)
  • Naoki HIRAYAMA, Hiroyuki OKAMURA, Keiji KIDANI, Hisanori IMURA
    2008 Volume 24 Issue 6 Pages 697-699
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A novel synergistic extraction system was investigated for the possible selective separation of light lanthanoids using an ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, as an extraction solvent and 2-thenoyltrifluoroacetone and 18-crown-6 as extractants. Trivalent lanthanum was efficiently extracted as a cationic ternary complex by the cation-exchange process, whereas europium and lutetium showed relatively low extractability without forming respective ternary complexes. This result is thought to originate in a size-fitting effect of 18-crown-6 to lanthanum and the unique nature of the ionic liquid as a chelate extraction solvent.
    Download PDF (526K)
Reviews
  • Noboru KITAMURA, Kosei UENO, Haeng-Boo KIM
    2008 Volume 24 Issue 6 Pages 701-710
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    The paper describes the fabrication and chemical applications of polymer microchannel chips, with special reference to in situ observations of the chemical/physical processes occurring in polystyrene microchannel chips, including those in microchannel-microelectrode/microheater chips. On the basis of absorption/fluorescence microspectroscopy and microelectrochemistry techniques, we show some characteristic features of liquid/liquid extraction, electrochemical responses, and photochemical/electrochemical/thermal synthetic reactions in microchannel chips.
    Download PDF (1277K)
Original Papers
  • Julia GALANDOVA, Guzel ZIYATDINOVA, Jan LABUDA
    2008 Volume 24 Issue 6 Pages 711-716
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A novel electrochemical DNA-based biosensor for the detection of deep DNA damage was designed employing the bionanocomposite layer of multiwalled carbon nanotubes (MWNT) in chitosan (CHIT) deposited on a screen printed carbon electrode (SPCE). The biocomponent represented by double-stranded (ds) herring sperm DNA was immobilized on this composite using layer-by-layer coverage to form a robust film. Individual and complex electrode modifiers are characterized by a differential pulse voltammetry (DPV) with the DNA redox marker [Co(phen)3]3+, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) with [Fe(CN)6]3- as a redox probe in a phosphate buffer solution (PBS). A good correlation between the CV and EIS parameters has been found, thus confirming a strong effect of MWNT on the enhancement of the electroconductivity of the electrode surface and that of CHIT on the MWNT distribution at the electrode surface. Differences between the CV and EIS signals of the electrodes without and with DNA are used to detect deep damage to DNA, advantageously using simple working procedures in the same experiment.
    Download PDF (798K)
  • Kazuharu SUGAWARA, Atsushi SENBONGI, Naoto KAMIYA, George HIRABAYASHI, ...
    2008 Volume 24 Issue 6 Pages 717-720
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    The binding between glucose residues and wheat germ agglutinin (WGA) on thionine/glucose-modified magnetic microbeads was evaluated using voltammetry. Thionine is an electroactive compound and has two amino groups. Thionine was immobilized to magnetic beads via cross-linking of the amino groups on the beads with an amino group on thionine. Glucose was bound to the other amino group of thionine via the formation of a Schiff base. The beads were only several micrometers in size the same size, as cells. WGA-binding to glucose on the bead surface blankets the thionine moiety. Thus, WGA-binding could be detected as a decrease in peak current of the thionine moiety.
    Download PDF (643K)
  • Abdolkarim ABBASPOUR, Abdolreza KHAJEHZADEH, Abolhassan NOORI
    2008 Volume 24 Issue 6 Pages 721-725
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A method for the determination of ascorbic acid in vitamin C tablets based on a very simple paptode design on TLC strips is described. This procedure is based on the reduction of iron(III) with ascorbic acid and the formation of a colorful red complex with immobilized 2,2′-dipyridyl (dipy) on TLC strips. The linear range of the system was 20 - 200 ppm with a detection limit of 1 ppm and a relative standard deviation of 1.5% (n = 28). The parameters, such as pH, concentration of iron(III), concentration of dipy and the volume of dipy per 1 cm2 of TLC strips, were optimized. The proposed sensor was successfully applied for the determination of ascorbic acid in vitamin C tablets.
    Download PDF (670K)
  • Nikoleta URBANOVÁ, Mihály KÁDÁR, Klá ...
    2008 Volume 24 Issue 6 Pages 727-733
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    Fluorescent sensor molecules were synthesized by conjugation of iminodiacetamide derivatives with fluorescent moieties of different structures and their UV-visible and fluorescent properties were characterized in acetonitrile solvent. The fluorescent measurements revealed that the N-(2-naphthyl) and N-phenyl derivatives exhibit a distinct zinc ion-selectivity over alkali and alkaline earth metal ions, while N-(anthrylmethyl) and N-(3-methoxyphenyl) derivatives do not possess any ion-selectivities. In contrast to the fluorescent measurements, all ligands show Zn2+ selectivity over Ca2+ and Mg2+ ions in plasticized PVC membranes using potentiometric signal transduction. This observation found for N-(anthrylmethyl) and N-(3-methoxyphenyl) derivatives can be ascribed to the more hindered interaction between the signalling group of the ionophore and the central metal ion in PVC membranes than in acetonitrile solution upon complexation. From the fluorescent measurements it can also be concluded that the ligands with metal ions form complexes mainly with 2:1 stoichiometry (L2M). On complex formation a considerable decrease in the fluorescent intensity was observed for all ligands except the N-(anthrylmethyl) derivative, where a 25 - 30 fold fluorescence enhancement was found, which is explained by the photoinduced electron transfer (PET) mechanism. All ionophores exhibited serious hydrogen ion interference, therefore complexation-induced spectral changes were measured in aprotic acetonitrile solution.
    Download PDF (807K)
  • Tomoharu SAKAI, Hiroyuki NAKAGAWA, Shinya KITAGAWA, Hajime OHTANI
    2008 Volume 24 Issue 6 Pages 735-738
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    Dual-gradient capillary electrochromatography (DG-CEC) was developed to provide superior performance with regard to the separation of ionized analytes; in this method, both the eluent composition and the applied voltage are varied during the separation procedure. As for the gradient in the eluent composition, a shift in the pH is employed to control not only the electrophoretic mobility, but also the retention factor of the analytes. The dual-gradient method was shown to be effective in increasing the resolution and reducing the chromatographic period of ionized analytes. Fourteen kinds of o-phthalaldehyde labeled amino acids were separated within 8 min using DG-CEC with multistage enlargement in the applied voltage. The separation efficiency increased particularly for highly retained amino acids in the dual-gradient, as compared to those in the ordinary single-gradient for the eluent.
    Download PDF (640K)
  • Naoki SURUGAYA, Toshiaki HIYAMA, Masaru WATAHIKI
    2008 Volume 24 Issue 6 Pages 739-744
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A robotized sample-preparation method for the determination of Pu, which is recovered by extraction reprocessing of spent nuclear fuel, by isotope dilution mass spectrometry (IDMS) is described. The automated system uses a six-axis industrial robot, whose motility is very fast, accurate, and flexible, installed in a glove box. The automation of the weighing and dilution steps enables operator-unattended sample pretreatment for the high-precision analysis of Pu in aqueous solutions. Using the developed system, the Pu concentration in a HNO3 medium was successfully determined using a set of subsequent mass spectrometric measurements. The relative uncertainty in determining the Pu concentration by IDMS using this system was estimated to be less than 0.1% (k = 2), which is equal to that expected of a talented analyst. The operation time required was the same as that for a skilled operator.
    Download PDF (793K)
  • Yasuhiro SUZUKI, Hitomi S. KIKKAWA, Masaaki KASAMATSU, Yoshiyasu HIGAS ...
    2008 Volume 24 Issue 6 Pages 745-749
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    The effect of heating on the refractive index (RI) and trace elemental compositions of glass was investigated in order to develop an accurate discrimination method of glass fragments exposed to the high temperature of fire on illegal entrance into a crime scene for robbery. Fragments taken from 5 different sheet glasses were subjected to RI measurement and analysis of trace elements using ICP-MS before and after heating at 764°C for 2 min. The difference in the RI between the heated and non-heated fragments ranged from 0.0012 to 0.0015, which corresponds to 6 times more than the variation of the RI within a pane of glass. In contrast, profiles of 10 elements (Co, Rb, Sr, Zr, Mo, Ba, La, Ce, Nd and Pb) in glass exhibited no significant difference between the heated and non-heated ones. In conclusion, the forensic discrimination of glass fragments must be performed not by RI measurement, but by analysis of the elemental compositions when glass evidence could be exposed to the high temperature of fire.
    Download PDF (686K)
  • Ugur SAHIN, Senol KARTAL, Ahmet ÜLGEN
    2008 Volume 24 Issue 6 Pages 751-757
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A coprecipitation method has been developed for the determination of Cr(III), Mn(II), Fe(III), Co(II), Cu(II), Cd(II) and Pb(II) ions in aqueous samples by flame atomic absorption spectrometry (FAAS) with the combination of pyridine, nickel(II) as a carrier element and potassium thiocyanate as an auxiliary complexing agent. The obtained coprecipitates were dissolved with nitric acid and measured by FAAS. The coprecipitation conditions, such as the effect of the pH, amounts of nickel, pyridine and potassium thiocyanate, sample volume, and the standing time of the precipitate formation were examined in detail. It was found that the metal ions studied were quantitatively coprecipitated with tetrakis(pyridine)-nickel(II)bis(thiocyanate) precipitate (TP-Ni-BT) in the pH range of 9.0 - 10.5. The reliability of the results was evaluated by recovery tests, using synthetic seawater solutions spiked with the analyte metal ions. The obtained recoveries ranged from 96 to 101% for all of the metal ions investigated. The proposed method was validated by analyses of two certified reference materials (NIST SRM 2711 Montana soil and HPS Certified Waste Water Trace Metals Lot #D532205). It was also successfully applied to seawater and dialysis solution samples. The detection limits (n = 25, 3s) were in the range of 0.01 - 2.44 µg l-1 for the studied elements and the relative standard deviations were ≤6%, which indicated that this method could fully satisfy the requiremets for analysis of such samples as seawater and dialysis solution having high salt contents.
    Download PDF (808K)
  • Grazyna WEJNEROWSKA, Alicja GACKOWSKA, Jerzy GACA
    2008 Volume 24 Issue 6 Pages 759-762
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A new method for the determination of linoleic acid (LA) in toothpaste by a routine analysis has been proposed. Studies were based on the ISO 5509 procedure, which was modified for the purpose of LA determination in the toothpaste. Gas chromatography (GC) was employed for the qualitative and quantitative determination of linoleic acid methyl ester. The content of LA (5.31%) in sunflower oil added to the toothpaste composition (0.5%) was determined, and then the optimization studies for the determination of LA in the toothpaste samples were carried out. The relative standard deviation (RSD) of the procedure developed was 9.96% (n = 9). The quantitative analysis showed that the content of LA in the toothpaste samples studied was 0.0258 ± 0.0011%. The detection limit of LA in toothpaste was approximately 0.001%.
    Download PDF (569K)
  • Ersin KILINC, Adnan CETIN, Mahmut TOGRUL, Halil HOSGOREN
    2008 Volume 24 Issue 6 Pages 763-768
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    C2-Symmetric two bis(amino alcohol)oxalamides (diamidediols) were synthesized and fully characterized. A new method was developed and successfully applied for the simultaneous preconcentration of both trace and toxic metals in water, by using C2-symmetric compounds. Under the optimum experimental conditions (i.e. pH = 10.0 ± 0.2, 2.75 × 10-3 mol L-1 N,N′-bis[(1R)-1-ethyl-2-hydroxyethyl]ethanediamide (DAD1), 1.75 × 10-3 mol L-1 N,N′-bis[(1S)-1-benzyl-2-hydroxyethyl]-ethanediamide (DAD2), 0.10% w/v octylphenoxy-polyethoxyethanol (Triton X-114)), calibration graphs were linear in the range of 2.5 - 25.0 ng mL-1 for Cu and Cd, 5.0 - 25.0 ng mL-1 for Co and Ni. The enrichment factors were 18, 23, 18 and 20 for Cd, Cu, Co and Ni in the case of DAD1, respectively; 20, 22, 17 and 20 for Cd, Cu, Co and Ni in the case of DAD2. The limits of detection for DAD1 were found to be 0.45, 0.50, 1.25 and 0.60 ng mL-1 for Cd, Cu, Co and Ni, respectively, and for DAD2 were found to be 0.44, 0.25, 0.60 and 1.55 ng mL-1 for Cd, Cu, Co and Ni, respectively. The developed method was applied to the determination of Cu, Cd, Co and Ni in water samples and certified reference materials with satisfactory results.
    Download PDF (730K)
  • Jorgovanka BOJIC, Blaga RADOVANOVIC, Jasmina DIMITRIJEVIC
    2008 Volume 24 Issue 6 Pages 769-774
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A rapid, relatively sensitive, and low-cost method for the determination of water-soluble urea content in dermatological therapy products and cosmetics is proposed using a new spectrophotometric assay with water as the only extraction solvent. Spectrophotometric methods involve addition of a known excess of bromate to urea in an acid medium, followed by the determination of residual bromine and chlorine reacting with methyl orange and measurement of absorbance at 505 nm. The absorbance increases linearly with urea concentration (r = 0.9998). The systems obey Beer's law for 6 - 90 µg ml-1. The calculated apparent molar absorbance values are found to be 4.537 × 103 dm3 mol-1 cm-1 and the Sandell's sensitivity is 0.013 µg cm-2. The variables affecting the rate of the reaction were investigated. The relative standard deviation for five-replication determination of 60 µg ml-1 urea was 2.1% and the detection limit of the method is 0.34 ng ml-1.
    Download PDF (714K)
  • Longfei CAI, Chunxiu XU
    2008 Volume 24 Issue 6 Pages 775-778
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    This article was retracted. See the retraction.
    Download PDF (647K)
  • Abbas AFKHAMI, Maryam ABBASI-TARIGHAT
    2008 Volume 24 Issue 6 Pages 779-783
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    In the present study, chemometric analysis of visible spectral data of phospho-and silico-molybdenum blue complexes was used to develop artificial neural networks (ANNs) for the simultaneous determination of the phosphate and silicate. Combinations of principal component analysis (PCA) with feed-forward neural networks (FFNNs) and radial basis function networks (RBFNs) were built and investigated. The structures of the models were simplified by using the corresponding important principal components as input instead of the original spectra. Number of inputs and hidden nodes, learning rate, transfer functions and number of epochs and SPREAD values were optimized. Performances of methods were tested with root mean square errors prediction (RMSEP, %), using synthetic solutions. The obtained satisfactory results indicate the applicability of this ANN approach based on PCA input selection for determination in highly spectral overlapping. The results obtained by FFNNs and by RBF networks were compared. The applicability of methods was investigated for synthetic samples, for detergent formulations, and for a river water sample.
    Download PDF (690K)
Notes
Advancements in Instrumentation
  • Shizuo FUJIWARA, Kozo SHIRATO, Norio HIGUCHI, Mizuho MAEKAWA, Naoto SH ...
    2008 Volume 24 Issue 6 Pages 813-815
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    A new apparatus has been built that annexes a normal electrocardiograph, ECG, with the aim to enhance its capacity. It adds the normal ECG power to superpose multiple records of ECG altogether and averages out them and, further, makes sophisticated analysis, such as normalizing the peak heights, evaluating the half-line widths of the peaks, or that of the standard deviations of measurements like the inter peak distances. The results of the said calculations have not been obtainable using the former instruments, and are expected to be useful for clinicians.
    Download PDF (621K)
  • Hiroshi AOKI, Takashi IKEDA, Masaki TORIMURA, Hiroaki TAO
    2008 Volume 24 Issue 6 Pages 817-821
    Published: 2008
    Released on J-STAGE: June 10, 2008
    JOURNAL FREE ACCESS
    We have developed an 8-ch capillary-based dispensing workstation with a variable capillary pitch mechanism. The capillary intervals can be varied from 1 to 9 mm to dispense different solutions simultaneously at an arbitrary dispensing pitch, allowing direct dispensing from microplates to integrated analytical systems. To evaluate the precision of its dispensing performance, droplets of Rhodamine G dye were dispensed onto glass slides and the values of the optical volume were analyzed. The error in the dispensed volume proved to be 0.54 nL when dispensing 20 nL. In dispensing small volumes, the volume error for this workstation was found to be about 100-fold less than that seen in conventional dispensers. Even highly viscous solutions containing 50% glycerol could be dispensed with precision. Rapid dispensing was also achieved. Moreover, the application of the workstation to preparing addressable 8 × 12 microsensor array chips was demonstrated, providing an independent and reproducible spot array.
    Download PDF (705K)
Announcements
feedback
Top