RADIOISOTOPES
Online ISSN : 1884-4111
Print ISSN : 0033-8303
ISSN-L : 0033-8303
Volume 54 , Issue 12
Showing 1-5 articles out of 5 articles from the selected issue
  • Keiko TAGAMI, Ikuko HIRAI, Shigeo UCHIDA
    2005 Volume 54 Issue 12 Pages 577-585
    Published: December 15, 2005
    Released: March 01, 2011
    JOURNALS FREE ACCESS
    In the national and international guidelines for drinking water quality, it is recommended that arsenic (As) and selenium (Se) concentrations in drinking water do not exceed 0.01 mg L-1 (10 μg L-1) . Since As and Se concentrations are thought to be lower than 1/10 of the recommended values in>90% of surface river waters, it is difficult to describe nationwide As and Se concentration levels in Japan. The recently developed octapole reaction system for inductively coupled plasma mass spectrometry (ORS-ICP-MS) could achieve low detection limits for As and Se compared to atomic absorption spectrometry and ICP optical emission spectrometry. In this study, direct measurement of trace levels of As and Se in river water for 25 major rivers, 10 samplings per river, were carried out using ORS-ICP-MS. In order to determine As and Se, He gas and H2 gas, respectively, were introduced into the ORS as reaction gas.
    The concentrations of As and Se were determined in more than 95% of the samples, and the cumulative probability distributions of these elements were on log-normal lines. Their respective geometric mean concentrations were calculated as 0.68μg L-1 and 0.062μg L-1, and the values were lower than the recommended ones. The concentration ranges of these elements in ten samples collected from the upper stream to the river mouth were usually narrow. Possibly, the observed concentrations originated from weathering of bedrock.
    Download PDF (907K)
  • Misato AMITANI, Sotaro MOMOSAKI, Hitomi TAGUCHI, Rie HOSOI, Jun HATAZA ...
    2005 Volume 54 Issue 12 Pages 587-592
    Published: December 15, 2005
    Released: March 01, 2011
    JOURNALS FREE ACCESS
    The dual tracer autoradiography using 18F-FDG and 14C-FDG was applied to the estimation of changes in the metabolic trapping rate in rat brain. Rats were infused with kainic acid (1μg/μL) into the right striatum 3 hours prior to the tracer experiment. 18F-FDG was intravenously injected into the rats, and 14C-FDG was injected 44 minutes after 18F-FDG injection. The rats were decapitated at 1 minute post-injection of 14C-FDG, and frozen brain sections were prepared. The slices were exposed on imaging plate for 1 hour, and 18F-FDG images (45 minutes) were obtained. After the decay of 18F, the same slices were contacted with imaging plate for 1 week, and 14C-FDG images (1 minute) were obtained. Radioactivity concentrations in cerebral cortex at 1 minute and 45 minutes after 18F-FDG injection were determined by the dissection method, the values were used to normalize 18F-FDG and 14C-FDG image. The subtraction image was made by subtracting the normalized 14C-FDG image from the 18F-FDG image. In the results, intrastriatal infusion of kainic acid significantly enhanced the metabolic trapping process of FDG. The dual tracer autoradiography with 18F-FDG and 14C-FDG seems to be useful to assess the metabolic trapping rate of FDG in brain injury.
    Download PDF (3756K)
  • Tomoko NAKANO, Takashi SAITO, Jun SATO
    2005 Volume 54 Issue 12 Pages 593-597
    Published: December 15, 2005
    Released: March 01, 2011
    JOURNALS FREE ACCESS
    Concentration of 222Rn in well water at Meiji University, Kawasaki, Japan, was observed from 2000 to 2001. The 222Rn concentration in the groundwater ranged from 3 to 5 Bq/L. The variation pattern of monthly averaged concentration of 222Rn in the groundwater was similar to that of precipitation: the monthly averaged concentration in groundwater tended to increase in summer and autumn with large amount of precipitation and to decrease in winter and spring with small amount of precipitation. The variation pattern suggested that the precipitation may give rise to the mixing of groundwaters of different origins.
    Download PDF (642K)
  • Yuu ISHIMORI
    2005 Volume 54 Issue 12 Pages 599-608
    Published: December 15, 2005
    Released: March 01, 2011
    JOURNALS FREE ACCESS
    The radon measurement with a gas-filled ionization chamber is generally performed at many laboratories in Japan as a standard method. In this paper, the characteristics of the method have been examined as follows. The wall effects against the different filled gases, nitrogen and dry air, have been evaluated with Monte Carlo simulation. The columnar recombination has been also evaluated from two different ways; one is the common evaluation from the relationship between inverse of ionization current and inverse of applied voltage; another is the evaluation from the relationship between the ionization current in the different gas pressure and the wall effect expected in each pressure.Both results have been agreed with each other. As the total, the efficiencies of ionization chamber, volume of which is 1.5 L, are estimated to be 0.02706 Bq.fA-1 for nitrogen gas of 93.3 kPa and 0.02701 Bq.fA-1 for air of 101.3 kPa, and the values are very close to the conversion factor on the literatures within 3% of difference. Furthermore the effect by humidity has been preliminarily estimated, and the effect is almost -3% per 1 % of absolute humidity but it can be easily removed by the suitable dryer. These examinations have proven the method with a gas filled ionization chamber has high accuracy for radon measurement. An 241Am disk source was used with same methods to confirm the results above mentioned.
    Download PDF (987K)
  • Specialist Committee of Quantum Beam,
    2005 Volume 54 Issue 12 Pages 609-647
    Published: December 15, 2005
    Released: July 21, 2010
    JOURNALS FREE ACCESS
feedback
Top