Shinku
Online ISSN : 1880-9413
Print ISSN : 0559-8516
ISSN-L : 0559-8516
Volume 8, Issue 10
Displaying 1-3 of 3 articles from this issue
  • Masatomo HASEGAWA
    1965 Volume 8 Issue 10 Pages 321-325
    Published: October 20, 1965
    Released on J-STAGE: September 29, 2009
    JOURNAL FREE ACCESS
    Download PDF (804K)
  • Tetsuro IZUMITANI
    1965 Volume 8 Issue 10 Pages 326-332
    Published: October 20, 1965
    Released on J-STAGE: September 29, 2009
    JOURNAL FREE ACCESS
    Download PDF (2144K)
  • Katsuya NAKAYAMA
    1965 Volume 8 Issue 10 Pages 333-337
    Published: October 20, 1965
    Released on J-STAGE: September 29, 2009
    JOURNAL FREE ACCESS
    This brief paper presents the vapoure pressure data of the following fluids used in vacuum pumps : DC 704, DC 705, Apiezon B, Apiezon C, Lion A, Di - 2 -ethylhexyl phthalate (DEHP), Di-2-ethyl- hexyl sebacate (DEHS), Cellulube 220, Cellulube 300, Convalex 10, and OS 124. Measurements have been made in the pressure range of 0. 5 to 20 Torr with the oil-manometer in which the samples themselves are used. It has been previously reported for this method to be most suitable in the case of measuring the vapour pressures of the vacuum pump oils near at a boiler temperature (J. Vac. Soc. Japan 1 222 (1958)). In discussion, the data obtained in study have been compared with those by other investigators. Consequently, it is proved that, this for each sample, all these data measured in the different range of pressure can be suffici-ently plotted on a line expressed by the equation, log P= a-b/T c log T.
    Download PDF (635K)
feedback
Top