分析化学
Print ISSN : 0525-1931
57 巻, 9 号
選択された号の論文の7件中1~7を表示しています
報文
ノート
  • 山崎 怜子, 中川 沙織, 田辺 顕子, 池内 健, 三井田 孝, 大和 進
    原稿種別: ノート
    2008 年57 巻9 号 p. 707-713
    発行日: 2008年
    公開日: 2008/11/07
    ジャーナル フリー
    A simple pretreatment method for the determination of 24S-hydroxycholesterol in human cerebrospinal fluid by gas chromatography/mass spectrometry (GC/MS) has been developed. Esterified cholesterol was saponified by a high concentration of potassium hydroxide (25 M, 1 mL) in a small volume (10 mL) of a conical test tube with a stopper made of glass. Next, free cholesterol was extracted with a small volume of n-hexane. The combined extracts obtained by the twice extraction were then applied on a silica cartridge for solid-phase extraction. A slight amount of 24S-hydroxycholestertol was separated from a large amount of cholesterol using n-hexane and ethylacetate as an elution solvent. 24S-hydroxycholestertol and 27-hydroxycholesterol-26,26,26,27,27-D5 as an internal standard were converted to trimethylsilyl ethers by the trimethylsilyl (TMS) reagent, and then the TMS derivatives were determined by GC/MS. The method was successfully applied to the determination of 24S-hydroxycholestertol in human cerebrospinal fluid from patients of non-neurodegenerative disorders. The pretreatment method reported here was simple and useful for one multi-specimen material pretreatment.
分析化学総説
  • 下坂 琢哉
    原稿種別: 分析化学総説
    2008 年57 巻9 号 p. 715-740
    発行日: 2008年
    公開日: 2008/11/07
    ジャーナル フリー
    近年SI単位に基づいたトレーサブルな標準ガスによる機器の校正が必要となりつつあるが,標準ガス濃度の不確かさを小さくするには高感度分析法が必要である.また,半導体技術の向上に伴い,原料ガスやパージガス中の水などの不純物の測定が重要となっている.本稿では,最初に高感度分析法により標準ガスの精度が向上する理由について述べ,次に標準ガスの調製に用いられる高純度ガス中の不純物を高感度に測定する手法・研究について詳説した.それらの分析法について実際の検出下限の比較を行うとともに,幾つかの手法についてはその原理や検出下限についての定量的な取り扱いを述べる.また,主に窒素・酸素・アンモニア中の不純物測定についてまとめた.不純物成分としては,メタン・二酸化炭素・一酸化炭素・アルゴン・酸素・窒素・水などを取り上げ,各マトリックスガス中でのそれら不純物成分の検出下限について述べる.
報文
  • 渡辺 邦洋, 四宮 麻記子, 小倉 隆, 四反田 功, 板垣 昌幸
    原稿種別: 報文
    2008 年57 巻9 号 p. 741-746
    発行日: 2008年
    公開日: 2008/11/07
    ジャーナル フリー
    分析に利用可能な発光系を探索し,金属イオン定量のための新規化学発光試薬を明らかにした.それらはクマリンの誘導体であり,数種の入手可能な誘導体のなかでウンベリフェロンが最も高感度でMn(II)の定量が可能であることを示した.操作法はフローインジェクション分析法により,ウンベリフェロンとMn(II)イオンを含む試料溶液に過酸化水素溶液を加える2流路で行った.カチオン性界面活性剤であるセチルトリメチルアンモニウムブロミドを添加することで化学発光強度は著しく増大した.化学発光を示す金属イオンにはMn(II)のほかにCu,Coがあり,Fe,Pbなども微弱な発光を示した.比較的高い試薬空試験値は金属などの不純物によるものではなく,Mn(II)イオンの触媒効果とは異なった反応機構があるものと推定された.0~1000 pptの範囲で相関係数0.989の直線関係が得られ,検出限界は0.8 ppt,定量下限は2.4 pptであった.本法は河川水中のMn(II)の定量に適用された.
技術論文
  • 宮下 正弘, 瀬山 義幸, 横山 次郎
    原稿種別: 技術論文
    2008 年57 巻9 号 p. 747-754
    発行日: 2008年
    公開日: 2008/11/07
    ジャーナル フリー
    ヨード強化卵(I卵)に含まれるヨウ化物イオン(I)を分析するため,I卵の卵黄0.05 g及び卵白0.5 gから,強陽イオン交換カートリッジ(Oasis MCX®)及び弱陰イオン交換カートリッジ(Oasis WAX®)を用いてIを固相抽出し,1 mLの分析試料を調製した.そして,この試料10 μLを紫外吸光検出法(検出波長: 225 nm)による逆相高速液体クロマトグラフィーで分析した.卵黄及び卵白中のIを繰り返し分析(n=4)した場合の定量値の相対標準偏差は0.8及び5.5% で,再現性は良好であった.また,卵黄1 g当たりに50 μg及び卵白1 g当たりに2.5 μgのIを添加して行った回収試験の回収率は92.4及び96.8% で,正確度も良好であった.Iの検出限界は,卵黄及び卵白各1 g当たり0.76及び0.08 μg(S/N=3)であった.本分析法を用いて市販のI卵(n=14)中のIの含量を調べた.
ノート
  • 鈴木 優治
    原稿種別: ノート
    2008 年57 巻9 号 p. 755-762
    発行日: 2008年
    公開日: 2008/11/07
    ジャーナル フリー
    In a qualitative test for urine protein by a test paper based on a protein error of tetrabromophenol blue, how the color development changes was examined by experiments and calculations when a pH change in the reaction mixture occurs in immersing a test paper in a urine sample whose pH may vary approximately from as low as 4.6 to as high as 7.8. In an experiment using bromophenol blue, the color development increased due to an increase in the pH of the reaction mixture, and the relative color intensity was closely associated with the magnitude of the pH change and the concentrations of the dye, buffer and protein. That is, even if the pH change by urine samples was equal, the relative color intensity differed with the concentrations of the dye, buffer and protein. It increased with an increase in the dye and buffer concentrations, and with a decrease in the protein concentration. These experimental results coincided well with those obtained by the calculation. It is important that the detection of a urine sample with a low protein concentration is carried out by using a test paper in which the dye concentration is low in order to suppress a false-positive result.
アナリティカルレポート
  • 磯山 直彦, 及川 真司, 御園生 淳, 中原 元和, 中村 良一, 鈴木 奈緒子, 吉野 美紀, 鈴木 千吉, 佐藤 肇, 原 猛也
    原稿種別: アナリティカルレポート
    2008 年57 巻9 号 p. 763-769
    発行日: 2008年
    公開日: 2008/11/07
    ジャーナル フリー
    For the purpose of marine environmental radioactivity monitoring, stable Cs and 137Cs concentrations were obtained from 214 marbled flounder (Pleuronectes yokohamae) samples collected from off the coast of Ibaraki prefecture in Japan in 2005 and 2006. Prior to the investigation, an analytical method for the determination of Cs in muscle of marbled flounder samples by inductively coupled plasma mass spectrometry (ICP-MS) was seriously considered from the view point of sample preparation (wet way) to a Cs measurement. Since major problems in determining Cs by the ICP-MS is the interference of matrix materials and molecular ions on Cs peak area (m/z 133), a known amount of In (m/z 115) was added to the sample solutions as an internal standard. To check the accuracy of the determination, duplication analysis and standard reference materials were used. Analytical results of Cs in muscles samples by ICP-MS agreed well with duplicated samples, and standard reference materials. The standard length and body weight were obtained from a total of 214 flounder samples. The stable Cs, stable K and 137Cs concentrations in muscle were determined by ICP-MS, flame photometry and radiochemical analysis, respectively. The mean standard length correlates closely with the mean body weight. The stable Cs concentration was in proportion to the body weight, also, the 137Cs concentration correlated closely with the stable Cs concentration in muscle. On the other hand, a stable K concentration was found to be uniform, and unrelated with 137Cs and stable Cs concentrations. The specific activities, the ratio of 137Cs/stable Cs in muscle, was found to be 5.5∼6.7 with an average of 6.2±0.35 (SD) among five different size groups of the standard length of marbled flounder samples. From these results, ICP-MS provided useful tools for the determination of a trace amount of Cs in muscle samples, combined with wet way pretreatment techniques. In addition, marbled flounder proved to be a useful species for comparing the radioactivity of fishes in coastal seas around Japan with each other in the environmental radioactivity monitoring program.
feedback
Top