A method for determining 0.0020.1% of tin in light alloys (Al-base and Mg-base alloy) was investigated, and the following procedure was established.
One gram of sample was dissolved with 40 m
l of 4
N hydrobromic acid and 12 drops of 30% H
2O
2. The solution was filtrated through a filter paper (No. 5A). The filter paper was then washed thoroughly with 4
N hydrobromic acid, and the solution was diluted with 4
N hydrobromic acid to 100.0 m
l. A 0.510 m
l portion of the solution was transferred to a 50 m
l separating funnel, and tin was extracted into ethylether from the 4
N HBr medium. The ether layer was transferred into 100 m
l beaker, and evaporated gently. The residue was dissolved with 2
N hydrobromic acid and transferred into a separating funnel. To the solution, 1.5 m
l of 0.5% Rhodamine B solution and 5 m
l of benzene were added, and the whole was shaken for 1 minute. The fluorescence intensity of the benzene solution was then measured.
These procedures took 45 minutes, and 0.0020.1% of tin in light alloys (Al-base and Mg-base alloy) could be determined.
抄録全体を表示